Ul Articulated Accessibility Probe and Iec Test Probe Major Difference Between

Another major difference between the UL and IEC standards is the probe used to determine accessibility of live parts and parts capable of causing injury, the UL Articulated Accessibility Probe and the IEC Test Finger as shown below:

1. UL Articulated Accessibility Probe

UL Articulated Accessibility Probe


2. IEC Test Finger (Test Probe B of IEC 61032)

IEC Test Finger

While both of these probes are applied to openings without appreciable force, if the IEC Test Finger does not enter an opening, the probe is applied in the straight position with a force of 20 N to determine if accessibility through the opening. The UL Articulated Accessibility Probe is applied to openings with a minor dimension of less than 1 in. (25.4 mm). When the minor dimension of the opening is greater, accessibility is determined by requiring no uninsulated live parts be located within a distance of five times the diameter of the largest rod which can be inserted through the opening.


3. IEC Test Pin

IEC Test Pin

In addition to the IEC Test Finger, for IEC 60335, the IEC Test Pin (Test Probe 13 of IEC 61032) is used to determine accessibility of live parts through openings in products without a means for earthing. It is also applied to products with a means for earthing, through openings in non-metallic enclosures and metal enclosures with a non-conductive coating.


4. IEC Test Probe

IEC Test Probe

For products with visibly glowing heating elements, such as toasters, the IEC Test Probe (Probe 41 of IEC 61032) is used to determine accessibility of these live parts. For UL, accessibility of an open wire heating element for all products is determined by use of the articulated accessibility probe except for an automatic toaster, since in operation the open-wire element of an automatic toaster is radiating heat and light, and is regarded as visibly glowing. In addition, the automatic toaster is required to have a double pole switching device to disconnect the heating elements from all conductors of the supply circuit when they are in an “unenergized” state.

    Standard:       IEC 61032 IEC 60061 IEC 60335 IEC 60529 IEC 60068 IEC 60695 VDE 0620 UL AS/NZS3112
    TAG:
IEC Test Probe Go No Go Gauge Spring Impact Hammer Integrating Sphere UL Probe Test IP Tester Test Equipment
 
Glow Wire Tester Impact Test Hammer Go Gauge UL Test Finger Probe Hipot Tester Test Probe Needle Impact Testing Machine
  Español   Español Svenska   Svenska لعربية   لعربية русский   русский Português   Português 中国  中国 Polski   Polski Română   Română Dansk   Dansk suomi   suomi
  Français   Français hrvatski   hrvatski Ελληνικά   Ελληνικά Nederlands   Nederlands česky   česky Deutsch   Deutsch 日本の   日本の Italia   Italia български   български นไทย   นไทย
test probe