IP Ratings (Ingress Protection)

A two-digit number established by the International Electro Technical Commission, is used to provide an Ingress Protection rating to a piece of electronic equipment or to an enclosure for electronic equipment.

The protection class after EN60529 are indicated by short symbols that consist of the two code letters IP and a code numeral for the amount of the protection.

Example: IP65 (NEMA 4)
The two digits represent different forms of environmental influence:
• The first digit represents protection against ingress of solid objects.
• The second digit represents protection against ingress of liquids.

The larger the value of each digit, the greater the protection. As an example, a product rated IP54 would be better protected against environmental factors than another similar product rated as IP42.

IP TABLE:

IP.. First digit:
Ingress of solid objects
Second digit:
Ingress of liquids
0 No protection No protection
1 Protected against solid objects over 50mm e.g. hands, large tools. Protected against vertically falling drops of water or condensation.
2 Protected against solid objects over 12.5mm e.g. hands, large tools. Protected against falling drops of water, if the case is disposed up to 15 from vertical.
3 Protected against solid objects over 2.5mm e.g. wire, small tools. Protected against sprays of water from any direction, even if the case is disposed up to 60from vertical.
4 Protected against solid objects over 1.0mm e.g. wires. Protected against splash water from any direction.
5 Limited protection against dust ingress.
(no harmful deposit)
Protected against low pressure water jets from any direction. Limited ingress permitted.
6 Totally protected against dust ingress. Protected against high pressure water jets from any direction. Limited ingress permitted.
7 N/A Protected against short periods of immersion in water.
8 N/A Protected against long, durable periods of immersion in water.
9k N/A Protected against close-range high pressure, high temperature spray downs.


IP protection of the PIP:

A PIP in the standard PIP housing is generally IP51 protected. Higher IP protection level with the standard PIP housing (up to IP54) can be reached with good positioning / orientation of the PIP. In other special PIP-housings, like a MIL-housing up to IP67 protection is possible.

IP protection of the PANEL-PIP:

The PANEL-PIP is available in various housings. Those allow a protection level of up to all around IP65.

    Standard:       IEC 61032 IEC 60061 IEC 60335 IEC 60529 IEC 60068 IEC 60695 VDE 0620 UL AS/NZS3112
    TAG:
IEC Test Probe Go No Go Gauge Spring Impact Hammer Integrating Sphere UL Probe Test IP Tester Test Equipment
 
Glow Wire Tester Impact Test Hammer Go Gauge UL Test Finger Probe Hipot Tester Test Probe Needle Impact Testing Machine
  Español   Español Svenska   Svenska لعربية   لعربية русский   русский Português   Português 中国  中国 Polski   Polski Română   Română Dansk   Dansk suomi   suomi
  Français   Français hrvatski   hrvatski Ελληνικά   Ελληνικά Nederlands   Nederlands česky   česky Deutsch   Deutsch 日本の   日本の Italia   Italia български   български นไทย   นไทย
test probe