contact us
products
- Main Products
- IEC Test Probe
- UL Test Probe
- Material Flammability Tester
- IP Code Tester
- Impact Test Apparatus
- Security Testing Machine
- Lamp Cap Gauge Tester
- Lampholders Gauge Tester
- Plug & Socket Tester
- Electrical Safety Tester
- LED Test Instruments
- Environmental Test Equipment
- Instrument Accessories
- Weighing Sensor
- Others Testing Equipment
technical articles
Company News
All Products
CAT. NO. | DESCRIPTION |
LX-2094MI | MULTITESTER |
LX-DV-20 | WATER DISTILLER (20l/h) |
LX-DV-8 | WATER DISTILLER (8l/h) |
LX-KK-3500 | CLIMATIC CHAMBER 3552 L (1200x1600x1850 mm), 10°C to + 70 °C, RH 30 to 95 % |
LX-KK1000 | CLIMATIC CHAMBER 1000 L, 5°C to + 95 °C, RH 15 to 95 % |
LX-KK1000 CHL | CLIMATIC CHAMBER 1000 L (1000x1000x1000 mm), -30°C to + 100 °C, RH 10 to 95 % |
LX-KK1000 CHLT | CLIMATIC CHAMBER 1000 L (1000x1000x1000 mm), -75°C to + 180 °C, RH 10 to 98 % |
LX-KK1000CH | CLIMATIC CHAMBER 1000 L (1000x1000x1000 mm), -45 °C to 120 °C, RH 15 to 97 % |
LX-KK105 | CLIMATIC CHAMBER 105 L, 5°C to + 95 °C, RH 15 to 95 % |
LX-KK1440CH | CLIMATIC CHAMBER 1440 L (1000x1200x1200 mm), 10°C to + 180 °C, RH 10 to 95 % |
LX-KK190 | CLIMATIC CHAMBER 190 L, 5°C to + 95 °C, RH 15 to 95 % |
LX-KK190LT | CLIMATIC CHAMBER 190 L, EXTENDED TEMP RANGE, -75°C to + 180 °C, RH 15 to 95 % |
LX-KK2000CH | CLIMATIC CHAMBER 2000 L (1050 x 1200 x 1600 mm), -40°C to + 150 °C, RH 10 to 98 % |
LX-KK265 | CLIMATIC CHAMBER 252 L, 5°C to + 95 °C, RH 15 to 95 % |
LX-KK4075 | CLIMATIC CHAMBER 4075 L, 5°C to + 95 °C, RH 15 to 95 % |
LX-KK500 | CLIMATIC CHAMBER 495 L, 5°C to + 95 °C, RH 15 to 95 % |
LX-KK600L | TEMPERATURE AND HUMIDITY CHAMBER 612 L, T= -40..90 deg C, % RH 10..95% |
|
|
LX-OB-7/2 | CALIBRATION BATH 7L (LX-TCW +8°C to 250°C +/- 0,02 °C, ID100 mm x 230 mm) |
LX-OB-7/2H | CALIBRATION BATH 7L (LX-TCW -40°C to 130°C +/- 0,02 °C, ID100 mm x 230 mm) |
LX-SP105 | HEATING CHAMBER WITH FORCED CONVECTION Ta+5 to 300 deg.C 105 L |
LX-SP105C | HEATING CHAMBER WITH FORCED CONVECTION Ta+5 to 300 deg.C 105 L |
LX-SP1200CK | TEMPERATURE CHAMBER 1200 l , 0°C to 300 °C |
LX-SP120E | HEATING CHAMBER WITH FORCED CONVECTION - EASY Ta+5 to 300 deg.C 120 L |
LX-SP1300C | HEATING CHAMBER WITH FORCED CONVECTION Ta+5 to 300 deg.C 1288 L |
LX-SP160 | HEATING CHAMBER WITH FORCED CONVECTION Ta+5 to 300 deg.C 163 L |
LX-SP160C | HEATING CHAMBER WITH FORCED CONVECTION Ta+5 to 300 deg.C 163 L |
LX-SP190 | HEATING CHAMBER WITH FORCED CONVECTION Ta+5 to 300 deg.C 190 L |
LX-SP190C | HEATING CHAMBER WITH FORCED CONVECTION Ta+5 to 300 deg.C 190 L |
LX-SP210 | HEATING CHAMBER WITH FORCED CONVECTION Ta+5 to 300 deg.C 210 L |
LX-SP210C | HEATING CHAMBER WITH FORCED CONVECTION Ta+5 to 300 deg.C 210 L |
LX-SP240E | HEATING CHAMBER WITH FORCED CONVECTION - EASY Ta+5 to 300 deg.C 240 L |
LX-SP250 | HEATING CHAMBER WITH FORCED CONVECTION Ta+5 to 300 deg.C 250 L |
LX-SP250C | HEATING CHAMBER WITH FORCED CONVECTION Ta+5 to 300 deg.C 250 L |
LX-SP25E | HEATING CHAMBER WITH FORCED CONVECTION - EASY Ta+5 to 300 deg.C 25 L |
LX-SP265 | HEATING CHAMBER WITH FORCED CONVECTION Ta+5 to 300 deg.C 264 L |
LX-SP265C | HEATING CHAMBER WITH FORCED CONVECTION Ta+5 to 300 deg.C 264 L |
LX-SP440 | HEATING CHAMBER WITH FORCED CONVECTION Ta+5 to 300 deg.C 440 L |
LX-SP440C | HEATING CHAMBER WITH FORCED CONVECTION Ta+5 to 300 deg.C 440 L |
LX-SP45 | HEATING CHAMBER WITH FORCED CONVECTION Ta+5 to 300 deg.C 44 L |
LX-SP45C | HEATING CHAMBER WITH FORCED CONVECTION Ta+5 to 300 deg.C 44 L |
LX-SP55E | HEATING CHAMBER WITH FORCED CONVECTION - EASY Ta+5 to 300 deg.C 55 L |
LX-SP910C | HEATING CHAMBER WITH FORCED CONVECTION Ta+5 to 300 deg.C 910 L |
|
|
LX-T1-02 | HEATING DEVICE |
LX-T1-04 | HEATING DEVICE CONTROLLER |
LX-T1-11 | FUME CUPBOARD (PROTECTIVE CABINET, TEST CHAMBER) 850 l |
LX-T1-12 | FUME CUPBOARD (PROTECTIVE CABINET) 1000 x 1000 x 1500 mm |
LX-T1-13 | DUST CHAMBER 3 m3 |
|
|
LX-T1-15 | DUST CHAMBER 800x800x900 mm |
LX-T1-16 | DUST CHAMBER 2000x1000x1000 mm |
LX-T1-17 | DUST CHAMBER 1000x1000x1000 mm |
LX-T1-18 | DUST CHAMBER 1400x700x700 mm |
LX-T1-19 | DRIP BOX 700 x 700 mm |
LX-T1-20 | DRIP BOX 500 x 500 mm |
LX-T1-21 | DRIP BOX 500 x 1000 mm |
LX-T1-23 | WATER SUPPLY UNIT FOR DRIP BOX |
LX-T1-25 | TURNTABLE FOR DRIP BOX |
LX-T1-26 | TUBE FOR LX-SPRAY APPARATUS, R 200, ?60, ?90° |
LX-T1-27 | TUBE FOR LX-SPRAY APPARATUS, R 400, ?60, ?90° |
LX-T1-28 | TUBE FOR LX-SPRAY APPARATUS R 600 ?60,?90° |
LX-T1-29 | TUBE FOR LX-SPRAY APPARATUS, R 800, ?60, ?90° |
LX-T1-30 | TUBE FOR LX-SPRAY APPARATUS, R 1000, ?60, ?90° |
|
|
LX-T1-35 | TELESCOPE SUPPORT 270x180 |
LX-T1-36 | LX-SPRAY NOZZLE |
LX-T1-37 | WALL ELECTROLIFT FOR DRIP BOX |
LX-T1-40 | WALL CARRIER FOR DRIP BOX (700x700) (h=4000mm) |
LX-T1-41 | WATER JET HOSE NOZZLE DIA. 6,3 mm |
LX-T1-42 | WATER JET HOSE NOZZLE DIA. 12,5 mm |
LX-T1-43 | LX-SPLASH NOZZLE (IEC 60335-2-64, 60335-2-58, Fig. 101) |
LX-T1-45 | JET TEST SET |
|
|
LX-T1-55 | DRAUGHT - PROOF ENCLOSURE FOR LUMINARIES 2x2x2 m (IEC 60598-1, Annex D) |
LX-T1-56 | DRAUGHT - PROOF ENCLOSURE FOR LUMINARIES 2,5x1,8x3 m (IEC 60598-1, Annex D) |
LX-T1-59 | TEST ENCLOSURE FOR MEASUREMENT OF SMOKE DENSITY OF CABLES 3x3x3m (IEC 61034-1) |
LX-T1-60 | APPARATUS FOR HEATING TEST WITH 4 - 10 A FLUSH-MOUNTED APPLIANCE INLETS C16 (INSUL. SHROUD) |
LX-T1-61 | APP. FOR HEATING TEST WITH 4 - 10 A FLUSH-MOUNTED APPLIANCE INLETS C16A (INSUL. SHROUD) |
LX-T1-62 | APP. FOR HEATING TEST WITH 4 - 16 A SURFACE-MOUNTED APPLIANCE INLETS C22 (METAL SHROUD) |
LX-T1-63 | POWER REGULATOR FOR LX-T1-65 |
LX-T1-65 | WATER EVAPORATION APPARATUS FOR REFRIGERATORS (IEC 60335-2-24, Fig. BB.1) |
LX-T1-66 | WATER LX-SPILLAGE APPARATUS FOR REFRIGERATORS (IEC 60335-2-24, Fig. 101) |
LX-T1-71 | TUBE FOR LX-SPRAY APPARATUS, R 1200, ?60, ?90° |
LX-T1-75C | PROGRAMMABLE WALK IN CHAMBER 3x3x3m t - 40 °C to + 90 °C , 15% to 95% RH |
LX-T1-76 | PLYWOOD TEST CABINET 500 × 500 × 500 mm (IEC 60400 Cl. 17.1) |
LX-T1-77 | CHAMBER FOR WATER TESTS IPX1-4 WITH DRIP BOX (500x500mm), OSCILLATING TUBE (R200) AND TURNTABLE |
LX-T1-77A | WATER DISTILLER WITH PUMP FOR CLEANING THE LX-T1-77 AFTER TESTING |
LX-T1-77B | SYSTEM FOR WATER RECYCLING OF LX-T1-77 |
LX-T1-78 | HEATING ENCLOSURE FOR THERMALLY PROTECTED BALLASTS (IEC 61347-1) |
LX-T1-79 | TEST CHAMBER FOR MEASUREMENT OF SMOKE DENSITY OF CABLES BURNING UNDER DEFINED CONDITIONS 3x3x3m (IEC 61034-1, 60331-11) |
LX-T2-01 | TUMBLING BARREL h=350mm |
LX-T2-02 | TUMBLING BARREL h=500 mm |
LX-T2-04 | TUMBLING BARREL |
LX-T2-04A | BARREL OF LX-T2-04 |
LX-T2-06 | PENDULUM IMPACT TEST APPARATUS - MECHANISM |
LX-T2-07 | MOUNTING DEVICE FOR IMPACT TEST m 10kg, 175 x 175 |
LX-T2-08 | MOUNTING DEVICE FOR IMPACT TEST DIA. 175 |
LX-T2-10 | BRAKE FOR LX-T2-11 WITH FASTENING DEVICE |
LX-T2-100 | DEVICE FOR CHECKING THE FIXATION OF PLUG PINS (VDE 0620-1 F. 31) |
LX-T2-101 | DEVICE FOR CHECKING THE FIXATION OF PLUG PINS (VDE 0620-1 F. 31) |
LX-T2-102 | DEVICE FOR CHECKING THE SIDE EARTHING CONTACTS (VDE 0620-1 F. 43) |
LX-T2-103 | G13 MOUNTING JIG FOR THE TESTING OF LAMPHOLDERS (IEC 60400, Fig. 1) |
LX-T2-104 | TOOL FOR VERIFICATION OF MAXIMUM WITHDRAWAL FORCE (NEN 1020) |
LX-T2-105 | TOOL FOR VERIFICATION OF MINIMUM WITHDRAWAL FORCE (NEN 1020) |
LX-T2-11 | TORSION APPARATUS 4 Nm |
LX-T2-12 | BENDING APPARATUS FOR LAMPHOLDERS (IEC 60238 Fig. 12) |
LX-T2-13 | DEVICE FOR WITHDRAWAL FORCE MEASURING |
LX-T2-14 | APPARATUS FOR VERIFICATION OF MAXIMUM WITHDRAWAL FORCE |
LX-T2-15 | PRESSURE APPARATUS (IEC 60238, Fig. 9) |
LX-T2-16 | APPARATUS FOR PRESSURE TEST ON SHROUDS (IEC 60320-1, F. 20) |
LX-T2-17 | APPARATUS FOR PULLING TEST (IEC 60320-1, F. 19) |
LX-T2-18 | APP. FOR TESTING THE CORD RETENTION |
LX-T2-19 | IMPACT APP. FOR GRIPPING LUGS |
LX-T2-20 | APPARATUS FOR TESTING CORD RETENTION (IEC 60884-1, Fig. 20) |
LX-T2-21 | IMPACT WEIGHT APPARATUS |
LX-T2-22 | INTERMEDIATE PE FOR LX-T2-21 FOR LOW TEMP. TEST |
LX-T2-23 | INTERMEDIATE PE FOR LX-T2-21 FOR PIN INSULATING SLEEVES |
LX-T2-25 | SLIDING WEIGHT 100 g FOR LX-T2-21 |
LX-T2-28 | SLIDING WEIGHT 250 g FOR LX-T2-21 |
LX-T2-34 | SLIDING WEIGHT 1000 g FOR LX-T2-21 |
LX-T2-40 | AXIAL PULL TEST APPARATUS (IEC 60127-2, Fig. 7) |
LX-T2-41 | TEST FUSE BASE I max.10A (IEC 60127-2, Fig. 1) |
LX-T2-42 | TEST FUSE BASE I > 10A (IEC 60127-2, Fig. 2) |
LX-T2-43 | TEST FUSE BASE FOR BREAKING CAPACITY (IEC 60127-2, Fig. 3) |
LX-T2-44 | MECHANICAL SHOCK TEST APPARATUS (IEC 60898-1) |
LX-T2-45 | BUMP TEST APPARATUS 1000 x 600 mm, IEC 60065 |
LX-T2-46 | PENDULUM IMPACT - TEST APPARATUS-POLYAMIDE HAMMER 150g |
LX-T2-47 | PENDULUM IMPACT-TEST APPARATUS-STEEL HAMMER 150g |
LX-T2-48 | PENDULUM IMPACT-TEST APPARATUS-STEEL HAMMER 250g |
LX-T2-49 | PENDULUM IMPACT-TEST APPARATUS-STEEL HAMMER 500g |
LX-T2-50 | PENDULUM IMPACT-TEST APPARATUS-STEEL HAMMER 1500g |
LX-T2-51 | PENDULUM IMPACT-TEST APPARATUS-STEEL HAMMER 5000g |
LX-T2-52 | MOUNTING BLOCK FOR FLUSH TYPE EQUIPMENT |
LX-T2-53 | TRIGGER FOR HAMMERS LX-T2-49, LX-T2-50 and LX-T2-51 |
LX-T2-54 | TORSION APPARATUS 20 Nm |
LX-T2-58 | TORSION APPARATUS 0.5 Nm (IEC 60335-1, 60950-1) |
LX-T2-59 | ARRANGEMENT FOR MECHANICAL STRENGTH TEST ON MULTIPLE PORTABLE SOCKET-OUTLETS (IEC 60884-1, BS 1363-2) |
LX-T2-60 | PENDULUM IMPACT-TEST APPARATUS-POLYAMIDE HAMMER 250g |
LX-T2-63 | TUMBLING BARREL h=500 mm (IEC60068-2-32) |
LX-T2-64 | ARRANGEMENT FOR COMPRESSION TEST OF 24.5 (150 N, 300 N) (IEC 60884-1, FIG. 8, Cl. 10.1) |
LX-T2-65 | APPARATUS FOR TESTING SCREW-TYPE&nbLX-SP;TERMINALS (IEC 60884-1, Fig. 11) |
LX-T2-66 | APPARATUS FOR TESTING DURABILITY OF MARKINGS ON RATING LABELS |
LX-T2-69 | ARRANGEMENT FOR CHECKING DAMAGE TO CONDUCTORS (IEC 60884-1, Fig. 11) |
LX-T2-70 | INCLINED PLANE 1000 x 1000 mm |
LX-T2-71 | TILTED SUPPORT FOR IPX2 TEST 500 x 500 |
LX-T2-72 | APPARATUS FOR WINDING A FLEXIBLE PIPE |
LX-T2-73 | APPARATUS FOR CHECKING SECURITY OF LAMPHOLDER CONTACTS |
LX-T2-74 | CORD ANCHORAGE TORQUE DEVICE |
LX-T2-76 | DEVICE FOR MEASURING THE CONTACT PRESSURE OF EARTHING CONTACTS OF 10/16A 250 V TWO-POLE SOCKET-OUTLETS WITH SIDE EARTHING-CONTACTS (F. 23, CEE 7, VDE 0620-1 F. 14) |
LX-T2-77 | PLUG PIN DEFLECTION TEST APPARATUS FOR RESILIENT PLUGS (BS 1363-1, Fig. 8, Cl. 12.12) |
LX-T2-78 | APPARATUS FOR MECHANICAL STRENGTH TEST ON RESILIENT COVERS WITH HARDWOOD BLOCK (BS 1363-1, Cl. 9, Fig. 2a, 2b) |
LX-T2-79 | APPARATUS FOR TESTS ON PLUG PINS (BS 1363-1, Fig. 32, Cl. 12.9.4) |
LX-T2-80 | APPARATUS FOR TORSION TEST ON PINS (BS 1363-1, Fig. 33, Cl. 12.9.6) |
LX-T2-81 | APPARATUS FOR PULL TEST ON BS PLUGS (100N, W/MOUNTING PLATE) (BS 1363-1, Fig. 7, Cl. 12.11.1) |
LX-T2-82 | TOOL FOR VERIFICATION OF MAXIMUM WITHDRAWAL FORCE (SSA 444, IEC 60884-1) |
LX-T2-83 | TOOL FOR VERIFICATION OF MAXIMUM WITHDRAWAL FORCE (EN 50075, IEC 60884-1) |
LX-T2-84 | TOOL FOR VERIFICATION OF MAXIMUM WITHDRAWAL FORCE (DIN 49406, IEC 60884-1) |
LX-T2-85 | TOOL FOR VERIFICATION OF MINIMUM WITHDRAWAL FORCE (SMALL SSA 444, IEC 60884-1) |
LX-T2-86 | TOOL FOR VERIFICATION OF MINIMUM WITHDRAWAL FORCE (LARGE SSA 444, IEC 60884-1) |
LX-T2-87 | TOOL FOR VERIFICATION OF MINIMUM WITHDRAWAL FORCE (DIN 49406, IEC 60884-1) |
LX-T2-88 | TOOL FOR VERIFICATION OF MINIMUM WITHDRAWAL FORCE (EN 50075, IEC 60884-1) |
LX-T2-89 | BUMP TEST APPARATUS 1500 x 1000 mm, 100 kg, IEC 60065 |
LX-T2-91 | G5 MOUNTING JIG FOR THE TESTING OF LAMPHOLDERS (IEC 60400, Fig. 1) |
LX-T2-92 | FIXTURE FOR THE TESTING OF LAMPHOLDER FLEXIBILITY (IEC 60400, Fig. 3) |
LX-T2-93 | TUMBLING BARREL h=500 mm (BS 1363-1, Fig. 20) |
LX-T2-94 | APPARATUS FOR CHECKING THE STABILITY OF SIDE EARTHING CONTACTS (VDE 0620-1 F. 15) |
LX-T2-95 | TEST PLUG 16 A (VDE 0620-1 F. 16A) |
LX-T2-96 | TEST PLUG 3-PHASE 16 A (VDE 0620-1 F. 16b) |
LX-T2-97 | TEST PLUG 3-PHASE 25 A (VDE 0620-1 F. 16c) |
LX-T2-98 | TEST PLUG 2,5 A (VDE 0620-1 F. 16d) |
LX-T2-99 | DEVICE FOR CHECKING THE FIXATION OF PLUG PINS (VDE 0620-1 F. 31) |
LX-T3-01 | EARTH BOND RESISTANCE TESTER 12 (6) V a.c., I max. 33A |
LX-T3-04 | APP. FOR SOCKET-OUTLETS BREAKING CAP. AND NORMAL OP. TEST |
|
|
LX-T3-06 | TEST CIRCUIT A FOR SWILX-TCHES |
LX-T3-07 | TEST CIRCUIT FOR SWILX-TCHES 200 A |
LX-T3-08 | TEST CIRCUIT FOR SWILX-TCHES 80 A |
LX-T3-09 | TEST CIRCUIT FOR SWILX-TCHES |
LX-T3-10 | APPARATUS FOR CIRCULAR AND ANGULAR MOVEMENTS |
LX-T3-12 | APPARATUS FOR NORMAL OPERATION TEST OF LAMPHOLDERS (FOR USE WITH LX-T3-10) |
LX-T3-13 | CABLE FLEXING APPARATUS |
LX-T3-15 | APPARATUS FOR AUTOMATIC REEL CORD TESTING |
LX-T3-20 | APPARATUS FOR FLEXING TEST (IEC 60884-1, BS 1343-1) |
LX-T3-25 | APP. FOR BREAKING CAPACITY AND NORMAL OPERATION TESTS (IEC 320) |
LX-T3-26 | APP. FOR BREAKING CAPACITY AND NORMAL OPERATION TESTS (DOUBLE SIDED, IEC 320) |
LX-T3-27 | APP. FOR SOCKET-OUTLETS BREAK. CAP. AND NORMAL OP. TEST (DOUBLE SIDED, IEC 884-1) |
LX-T3-30 | ADDITIONAL PARTS FOR LX-T3-10 FOR TOASTERS FLEXING TEST |
LX-T3-44 | PROBE FOR MEASURING SURFACE TEMPERATURE (IEC 60335-2-6) |
|
|
LX-T3-53A | THERMOCOUPLE WITH THE COPPER BLOCK Dia. 4 mm (IEC 60695-11-5, 60335-1, 60959-1) |
LX-T3-53B | THERMOCOUPLE WITH THE COPPER BLOCK Dia. 9 mm (IEC 60695-11-3, ASTM D 5027) |
LX-T3-53C | THERMOCOUPLE WITH THE COPPER BLOCK Dia. 5,5 mm (IEC/TS 60695-11-4, ASTM D 5027) |
LX-T3-54A | FLAME HEIGHT GAUGE (IEC 60695-11-5, 60335-1, 60959-1) |
LX-T3-54B | FLAME HEIGHT GAUGE (IEC/TS 60695-11-3) |
LX-T3-54C | FLAME HEIGHT GAUGE (IEC/TS 60695-11-4) |
LX-T3-54D | CLEARANCE GAUGE (IEC/TS 60695-11-4) |
|
|
LX-T3-62 | IMPULSE GENERATOR 10/700 ?s, 6 kV (IEC 60950, 61180-1, 61180-2) |
LX-T3-64 | APPARATUS FOR NORMAL OPERATION TESTS OF SOCKET OUTLETS (BS 1363-2, Cl. 18) |
|
|
LX-T4-04 | DEVICE FOR TESTING NON-SOLID PINS 100 N |
LX-T4-07 | GLOW WIRE TEST APPARATUS |
LX-T4-07A | THERMOCOUPLE FOR GLOW WIRE TEST APPARATUS |
LX-T4-07B | WIRE LOOP FOR GLOW WIRE TEST APPARATUS |
LX-T4-07T | TIMER FOR GLOW WIRE TEST APPARATUS |
|
|
LX-T4-08A | THERMOCOUPLE DIA. 0,5 mm FOR GLOW WIRE TEST APPARATUS |
LX-T4-08B | WIRE LOOP FOR GLOW WIRE TEST APPARATUS (FOR THERMOCOUPLE DIA. 0,5 mm) |
LX-T4-08D | SILVER FOIL 2 mm2 - 20 pcs. |
LX-T4-08E | THERMOCOUPLE DIA. 1 mm FOR GLOW WIRE TEST APPARATUS |
LX-T4-08F | WIRE LOOP FOR GLOW WIRE TEST APPARATUS (FOR THERMOCOUPLE DIA. 1 mm) |
LX-T4-08G | WIRE LOOP FOR GLOW WIRE TEST APPARATUS (STRAIGHT FOR THERMOCOUPLE DIA. 0,5 mm) |
LX-T4-08H | WIRE LOOP FOR GLOW WIRE TEST APPARATUS (STRAIGHT FOR THERMOCOUPLE DIA. 1 mm) |
LX-T4-09 | SOLDERABILITY TEST APPARATUS (IEC 60068-2-20/Test T: Test Ta Method 1, Test Tb Method 1A, 1B) |
LX-T4-10 | HIGH FREQUENCY LX-SPARK GENERATOR |
LX-T4-18 | APP. FOR PLUG PIN ABRASION (IEC 60884-1, BS 1363-1) |
LX-T4-19 | APPARATUS FOR COMPRESSION TEST FOR THE VERIFICATION OF RESISTANCE TO HEAT |
LX-T4-20 | ABRASION APPARATUS |
|
|
|
|
LX-T4-31 | NEEDLE FLAME BURNER DIA. 0.5 mm (IEC 60695-11-5) |
LX-T4-33 | BUNSEN BURNER |
LX-T4-34 | BUNSEN BURNER FISH TAIL |
LX-T4-36 | MECHANISMUS FOR BURNING TESTS (VERT. AND HORIZ.) |
LX-T4-37 | NEEDLE FLAME TESTER |
LX-T4-38 | BURNER TEST SET |
LX-T4-40 | POWER SUPPLY FOR LX-T4-53 |
|
|
LX-T4-41A | ELECTRODES FOR TRACKING TEST APPARATUS (PAIR) |
LX-T4-41C | NOZZLE FOR TRACKING TEST APPARATUS |
LX-T4-41D | DISTANCE GAUGE FOR TRACKING TEST APPARATUS |
LX-T4-41E | AMMONIUM CHLORIDE SOLUTION 1 l |
LX-T4-41F | CALIBRATED WEIGHTS M1 IN WOODEN BOXES, 1 g and 100 g WITH CERTIFICATES |
LX-T4-42 | TRACKING TEST APPARATUS (1000V) |
LX-T4-47 | APPARATUS FOR HIGH CURRENT ARCHING |
LX-T4-50 | ELECTRODE ARRANGEMENT 65 |
LX-T4-52 | APPARATUS FOR HIGH-VOLTAGE LOW-CURRENT ARCHING |
LX-T4-53 | TEST FIXTURE FOR HOT WIRE COIL IGNITABILITY TEST (IEC 60695-2-20, Fig. 3, IEC 60950-1) |
LX-T4-54 | WINDING DEVICE FOR HOT WIRE COIL IGNITABILITY TEST (IEC 60695-2-20, Fig. 4, IEC 60950-1) |
LX-T4-55 | NiCr WIRE 80/20, DIA. 0.5 mm, 100 m FOR HOT WIRE IGNITION TEST (IEC 60695-2-20, IEC 60950-1) |
LX-T4-56 | ELECTRODE ARRANGEMENT for EN 50 028 |
LX-T4-57 | MANDREL TEST APPARATUS (IEC 60950-1, Annex AA) |
LX-T4-58 | APPARATUS FOR SCRALX-TCHING COOLING SYSTEMS (IEC 60335-2-24, Fig. 102) |
LX-T4-59 | APPARATUS FOR TESTING RESISTANCE TO FLEXING AND ABRASION OF HOSES (IEC 60335-2-2, Fig. 101 and 102) |
LX-T4-61 | BURNER 1000W (IEC 60695-11-2) |
LX-T4-62 | GAS AND AIR SUPPLY UNIT FOR LX-T4-61 (FLOWMETERS ?2%) |
LX-T4-63 | GAS AND AIR SUPPLY UNIT FOR LX-T4-61 (FLOWMETERS ?4%) |
LX-T4-64 | METALLIC SCREEN WITH BURNER STAND (IEC 60332-1) |
LX-T4-65 | BURNER 50, 500 W (IEC 60695-11-4 A, IEC 60695-11-3 A) |
LX-T4-66 | GAS SUPPLY UNIT FOR LX-T4-65 and LX-T4-70 (ISO 9772, IEC 60695-11-3, 500W, FLOWMETER ?2%, VALVE AND MANOMETER) |
LX-T4-67 | GAS SUPPLY UNIT FOR LX-T4-65 (IEC 60695-11-4, 50W, FLOWMETER ?2%, VALVE AND MANOMETER) |
LX-T4-69 | APPARATUS FOR PRESSURE TEST (BS 1363-1, Fig. 23) |
LX-T4-70 | WING TOP BURNER (ISO 9772) |
LX-T4-70A | WING TOP FOR LX-T4-70 (ISO 9772) - LX-SPare part |
LX-T4-71 | SUPPORT GAUZE HOLDER (ISO 9772) |
LX-T4-72 | BURNER WITH VENTURI MIXER FOR BURNING CABLES 500 mm (IEC 60331-11) |
LX-T4-73 | GAS SUPPLY UNIT FOR LX-T4-72, LX-T4-61 (IEC 60331-11, IEC 60695-11-2, WITH MASS FLOWMETERS) |
LX-T4-74 | CABLE SUPPORTING ARRANGEMENT (IEC 60331-11) |
LX-T5-00 | GAUGE MAINTENANCE KIT |
LX-T5-08 | TEST CORNER 800 x 800 x 1200 mm, 480 THERMOCOUPLES |
LX-T5-101 | GAUGE FOR HOLES FOR BACKPLATE LAMPHOLDERS SCREWS (IEC 60238, Fig. 3) |
LX-T5-102 | E14 TEST CAP FOR NORMAL OPERATION TEST (IEC 60238, Fig. 5) |
LX-T5-103 | E27 TEST CAP FOR NORMAL OPERATION TEST (IEC 60238, Fig. 5) |
LX-T5-104 | E40 TEST CAP FOR NORMAL OPERATION TEST (IEC 60238, Fig. 5) |
LX-T5-105 | E27 GAUGE FOR DETECTING SIDE-CONTACTS WITH CUTTING-EDGES (7006-22B-1) |
LX-T5-106 | E27 GAUGE FOR TESTING PROTECTION AGAINST BULB-NECK DAMAGE AND FOR TESTING CONTACT-MAKING IN LAMPHOLDERS (7006-21-5) |
LX-T5-11 | E14 TEST CAP FOR TORQUE TESTS |
LX-T5-110 | E14 PLUG GAUGE FOR LAMPHOLDERS FOR TESTING CONTACT MAKING (7006-30-2) |
LX-T5-111 | E12 PLUG GAUGE FOR TESTING CONTACT MAKING (7006-25C-1) |
LX-T5-112 | E12 "NOT GO" PLUG GAUGE (7006-26B-1) |
LX-T5-113 | E12 "GO" PLUG GAUGE (7006-32A-1) |
LX-T5-114 | TEST PROBE "a" DIA. 12, EN 50144-2-5, IEC 60745-2-5 |
LX-T5-115 | E14 PLUG GAUGE FOR LAMPHOLDERS WITH CANDLE SHAPED SHAFT FOR CANDLE LAMPS FOR TESTING CONTACT MAKING (7006-30A-1) |
LX-T5-116 | SMALL TEST FINGER - test probe 19 |
LX-T5-117 | TEST ROD DIA. 8 X 230 mm (IEC 60335-2-14 cl. 20.102) |
LX-T5-118 | TEST PIN DIA. 3 x 100 mm |
LX-T5-119 | GAUGE FOR THE VERIFICATION OF THE OUTLINE OF COVERS OR COVER-PLATES |
LX-T5-12 | E27 TEST CAP FOR TORQUE TESTS |
LX-T5-120 | CYLINDRICAL STEEL ROD, DIA. 3 mm (IEC 60884-1, Cl. 24) |
LX-T5-122 | "NOT GO" GAUGE FOR E12 CAPS ON FINISHED LAMPS 7006-28C-1 |
LX-T5-123 | ALIGNMENT GAUGE FOR FUSE 5 x 20 mm (IEC 60127-2, Fig. 4) |
LX-T5-124 | ALIGNMENT GAUGE FOR FUSE 6.3 x 32 mm (IEC 60127-2, Fig. 4) |
LX-T5-125 | MAX. GAUGE FOR FUSES 5 x 20 mm |
LX-T5-126 | MIN. GAUGE FOR FUSES 5 x 20 mm |
LX-T5-127 | MAX. GAUGE FOR FUSES 6.3 x 32 mm |
LX-T5-128 | MIN. GAUGE FOR FUSES 6.3 x 32 mm |
LX-T5-129 | SOLID LINK FOR TEST ON FUSE CLIPS (BS 1363-1, Fig. 19, Cl. 20) |
LX-T5-13 | E40 TEST CAP FOR TORQUE TESTS |
LX-T5-130 | ELECTRICAL INDICATOR |
LX-T5-131 | DEVICE FOR CHECKING THE RESISTANCE TO LATERAL STRAIN OF 10/16A 250 V TWO-POLE FIXED SOCKET OUTLETS (IEC 60884-1, CEE 7) |
LX-T5-132 | GY6.35 GAUGE FOR CHECKING MIN. RETENTION FORCE OF CONTACTS IN LAMPHOLDERS (7006-59D-2) |
LX-T5-133 | G6.35, GX6.35 & GY6.35 "GO" GAUGE FOR LAMPHOLDERS 15 (7006-61B-4) |
LX-T5-134 | G6.35 & GX6.35 GAUGE FOR CHECKING MIN. RETENTION FORCE OF CONTACTS IN LAMPHOLDERS (7006-61C-4) |
LX-T5-135 | GX5.3 & GU5.3 SINGLE PIN GAUGE FOR CHECKING CONTACT MAKING IN LAMPHOLDERS (7006-73G-2) |
LX-T5-136 | GX5.3 GAUGE FOR CHECKING MAX. WITHDRAWAL FORCE OF CONTACTS IN LAMPHOLDERS (7006-73F-2) |
LX-T5-138 | ADDITIONAL "GO" GAUGE FOR E12 CAPS ON FINISHED LAMPS 7006-27J-1 |
LX-T5-139 | "GO" GAUGE FOR E12 CAPS ON FINISHED LAMPS (7006-27H-1) |
LX-T5-14 | E14 MANDREL FOR BENDING TEST (IEC 60238 Fig. 12) |
LX-T5-146 | GAUGE FOR FINISHED LAMPS FITTED WITH E40 CAPS FOR TESTING PROTECTION AGAINST ACCIDENTAL CONTACT (7006-53-1) |
LX-T5-147 | GAUGE FOR FINISHED LAMPS FITTED WITH E40 CAPS FOR TESTING CONTACT MAKING (7006-52-1) |
LX-T5-148 | "NOT GO" GAUGE FOR CAPS ON FINISHED LAMPS E40 (7006-28D-1) |
LX-T5-149 | "GO" GAUGE FOR CAPS ON FINISHED LAMPS E40 (7006-27-7) |
LX-T5-15 | E27 MANDREL FOR BENDING TEST (IEC 60238 Fig. 12) |
LX-T5-150 | E27 GAUGE "GO" C13A |
LX-T5-151 | E27 GAUGE "NOT GO" C13E |
LX-T5-152 | E33 GAUGE "GO" C13B |
LX-T5-153 | E33 GAUGE "NOT GO" C13F |
LX-T5-154 | R1? GAUGE "GO" C13C |
LX-T5-155 | R1? GAUGE "NOT GO" C13G |
LX-T5-156 | R2 GAUGE "GO" C13D |
LX-T5-157 | R2 GAUGE "NOT GO" C13H |
LX-T5-158 | E27 GAUGE "GO" C14A |
LX-T5-159 | E27 GAUGE "NOT GO" C14E |
LX-T5-16 | E40 MANDREL FOR BENDING TEST (IEC 60238 Fig. 12) |
LX-T5-160 | E33 GAUGE "GO" C14B |
LX-T5-161 | E33 GAUGE "NOT GO" C14F |
LX-T5-162 | R1? GAUGE "GO" C14C |
LX-T5-163 | R1? GAUGE "NOT GO" C14G |
LX-T5-164 | R2 GAUGE "GO" C14D |
LX-T5-165 | R2 GAUGE "NOT GO" C14H |
LX-T5-166 | E10 TEST CAP FOR TORQUE TESTS |
LX-T5-167 | E26 TEST CAP FOR TORQUE TESTS |
LX-T5-168 | E27 GAUGE FOR TESTING CONTACT MAKING AND PROT. AGAINST ACC. CON. DURING INSERTION (7006-22A-5) |
LX-T5-169 | E14 GAUGE FOR TESTING CONTACT MAKING AND PROT. AGAINST ACC. CON. DURING INSERTION (7006-31-5) |
LX-T5-17 | PUSH-PULL DYNAMOMETER 20N |
LX-T5-170 | W3/16 GAUGE "GO" C15A |
LX-T5-171 | W3/16 GAUGE "NOT GO" C15B |
LX-T5-172 | W3/16 GAUGE "GO" C15C |
LX-T5-173 | W3/16 GAUGE "NOT GO" C15D |
LX-T5-175 | D II. GAUGE C16A |
LX-T5-176 | D III. GAUGE C16B |
LX-T5-177 | D IV.H GAUGE C16C |
LX-T5-178 | D V.H GAUGE C16D |
LX-T5-18 | PUSH-PULL DYNAMOMETER 50N |
LX-T5-180 | D II. GAUGE C17A |
LX-T5-181 | D III. GAUGE C17B |
LX-T5-182 | D IV.H GAUGE C17C |
LX-T5-183 | D V.H GAUGE C17D |
LX-T5-185 | DEVICE FOR CHECKING THE RESISTANCE TO LATERAL STRAIN (DIN 49406, IEC 60884-1) |
LX-T5-186 | DEVICE FOR CHECKING THE RESISTANCE TO LATERAL STRAIN (SSA 444, IEC 60884-1) |
LX-T5-187 | DEVICE FOR CHECKING THE RESISTANCE TO LATERAL STRAIN (EN 50075, IEC 60884-1) |
LX-T5-19 | PUSH-PULL DYNAMOMETER 100N |
LX-T5-190 | E26 TEST CAP FOR TORQUE TESTS (7004-21A-2) |
LX-T5-191 | E12 TEST CAP FOR TORQUE TESTS (7004-28-2) |
LX-T5-192 | E17 TEST CAP FOR TORQUE TESTS (7004-26-2) |
LX-T5-193 | SKIRTED E26 TEST CAP FOR TORQUE TESTS (7004-130-1) |
LX-T5-194 | E26d TEST CAP FOR TORQUE TESTS (7004-29-2) |
LX-T5-195 | E27/51x39 TEST CAP FOR TORQUE TESTS (7004-27-3) |
LX-T5-196 | B22d TEST CAP FOR TORQUE TESTS (7004-10-7) |
LX-T5-197 | B15d TEST CAP FOR TORQUE TESTS (7004-11-6) |
LX-T5-198 | TEST PIN DIA. 1 x 60 mm, WITH 5 N LX-SPRING (BS 1363-2, Cl. 9.4.1) |
LX-T5-200 | CONTACT GAUGE 0,2 A (IEC 60320-1, F. 27) |
LX-T5-201 | NO CONTACT GAUGE 0,2 A (IEC 60320-1, F. 27) |
LX-T5-202 | CONTACT GAUGE 2,5 A (IEC 60320-1, F. 27) |
LX-T5-203 | NO CONTACT GAUGE 2,5 A (IEC 60320-1, F. 27) |
LX-T5-204 | CONTACT GAUGE 6 A (IEC 60320-1, F. 27) |
LX-T5-205 | NO CONTACT GAUGE 6 A (IEC 60320-1, F. 27) |
LX-T5-206 | CONTACT GAUGE 10 A (IEC 60320-1, F. 27) |
LX-T5-207 | NO CONTACT GAUGE 10 A (IEC 60320-1, F. 27) |
LX-T5-208 | CONTACT GAUGE 16 A (IEC 60320-1, F. 27) |
LX-T5-209 | NO CONTACT GAUGE 16 A (IEC 60320-1, F. 27) |
LX-T5-21 | TEST KNIFE SIZE 00 |
LX-T5-210 | GO GAUGE FOR CONNECTORS TO STANDARD SHEET C13 AND C17 (IEC 60320-1, FIG. 9F) |
LX-T5-211 | NOT-GO GAUGE FOR CONN. TO STANDARD SHEET C13 AND C17 (IEC 60320-1, FIG. 9G) |
LX-T5-212 | GO GAUGE FOR APPLIANCE INLETS TO STANDARD SHEETS C14, C16 AND C18 (IEC 60320-1, FIG. 9H) |
LX-T5-213 | GO GAUGE FOR CONN. TO STANDARD SHEET C15 (IEC 60320-1, FIG. 9J) |
LX-T5-214 | GO GAUGE FOR CONNECTORS TO STANDARD SHEET C15 A (IEC 60320-1, FIG. 9S) |
LX-T5-215 | NOT GO GAUGE FOR CONN. TO STANDARD SHEET C13, C15 & C17 (IEC 60320-1, FIG. 9R) |
LX-T5-216 | GO GAUGE FOR APPLIANCE INLETS TO STANDARD SHEET C16A (IEC 60320-1, FIG. 9T) |
LX-T5-22 | TEST KNIFE SIZE 0 |
LX-T5-220 | APPLIANCE INLET GAUGE FOR MAX. WITHDRAWAL FORCE CHECKING C14 (IEC 60320-1, Cl. 16) |
LX-T5-221 | APPLIANCE INLET GAUGE FOR MAX. WITHDRAWAL FORCE CHECKING - C16 (IEC 60320-1, Cl. 16) |
LX-T5-222 | APPLIANCE INLET GAUGE FOR MAX. WITHDRAWAL FORCE CHECKING - C16 A (IEC 60320-1, Cl. 16) |
LX-T5-225 | APPLIANCE INLET GAUGE FOR BREAKING CAPACITY TEST - C14 |
LX-T5-226 | APPLIANCE INLET GAUGE FOR BREAKING CAPACITY TEST - C16 |
LX-T5-23 | TEST KNIFE SIZE 1 |
LX-T5-235 | CONTACT GAUGE FOR EARTHING CONTACT 2,5 A |
LX-T5-236 | NO CONTACT GAUGE FOR EARTHING CONTACT 2,5 A |
LX-T5-237 | CONTACT GAUGE FOR EARTHING CONTACT 16 A |
LX-T5-238 | NO CONTACT GAUGE FOR EARTHING CONTACT 16 A |
LX-T5-24 | TEST KNIFE SIZE 2 |
LX-T5-25 | TEST KNIFE SIZE 3 |
LX-T5-250 | APPLIANCE INLET GAUGE FOR TEMPERATURE RISE MEASUREMENTS - C14 |
LX-T5-251 | APPLIANCE INLET GAUGE FOR TEMPERATURE RISE MEASUREMENTS - C16 |
LX-T5-252 | APPLIANCE INLET GAUGE FOR TEMPERATURE RISE MEASUREMENTS - C16 A |
LX-T5-253 | APPLIANCE INLET GAUGE FOR TEMPERATURE RISE MEASUREMENTS C22 |
LX-T5-259 | APPLIANCE INLET GAUGE FOR PULLING TEST - C24 |
LX-T5-26 | TEST KNIFE SIZE 4 |
LX-T5-260 | APPLIANCE INLET GAUGE FOR PULLING TEST C14 |
LX-T5-261 | APPLIANCE INLET GAUGE FOR PULLING TEST - C16 |
LX-T5-262 | APPLIANCE INLET GAUGE FOR PULLING TEST - C16 A |
LX-T5-263 | APPLIANCE INLET GAUGE FOR PULLING TEST - C2 |
LX-T5-264 | APPLIANCE INLET GAUGE FOR PULLING TEST - C6 |
LX-T5-265 | APPLIANCE INLET GAUGE FOR PULLING TEST - C8 |
LX-T5-266 | APPLIANCE INLET GAUGE FOR PULLING TEST - C10 |
LX-T5-267 | APPLIANCE INLET GAUGE FOR PULLING TEST - C18 |
LX-T5-268 | APPLIANCE INLET GAUGE FOR PULLING TEST - C20 |
LX-T5-269 | APPLIANCE INLET GAUGE FOR PULLING TEST - C22 |
LX-T5-27 | TEST KNIFE SIZE 4a |
LX-T5-270 | E14 TEST CAP A (IEC 60238, Fig. 13) |
LX-T5-273 | E14 TEST CAP B (IEC 60238, Fig. 13) |
LX-T5-274 | E27 TEST CAP B (IEC 60238, Fig. 14) |
LX-T5-275 | TEST CAP FOR LAMPHOLDERS E40 (IEC 60238 Fig. 15) |
LX-T5-276 | E27 GAUGE I. FOR TESTING RESILIENCE OF SIDE CONTACT (7006-22C-1) |
LX-T5-277 | E27 GAUGE II. FOR TESTING RESILIENCE OF SIDE CONTACT (7006-22D-1) |
LX-T5-28 | FOOT PROBE (EN 836, Fig. 3) |
LX-T5-280 | E14 TEST CAP FOR INSUL. RESISTANCE TESTING AND TEMP. RAISE MEASURING (IEC 60238 Fig. 11) |
LX-T5-281 | E27 TEST CAP FOR INSUL. RESISTANCE TESTING AND TEMP. RAISE MEASURING (IEC 60238 Fig. 11) |
LX-T5-282 | E40 TEST CAP FOR INSUL. RESISTANCE TESTING AND TEMP. RAISE MEASURING (IEC 60238 Fig. 11) |
LX-T5-283 | E10 TEST CAP FOR INSUL. RESISTANCE TESTING AND TEMP. RAISE MEASURING (IEC 60238 Fig. 11) |
LX-T5-284 | GAUGE FOR TESTING CONTACT-MAKING OF LAMPS FITTED WITH CAPS E26, E26/50x39,E26/51x39 & E26d (NON-SKIRTED) (7006-29-3) |
LX-T5-285 | E26d GAUGE FOR CAPS ON FINISHED LAMPS FOR TESTING PROTECTION AGAINST ACCIDENTAL CONTACT (7006-29A-2) |
LX-T5-286 | E26d GAUGE WITH REFERENCE DIAMETER OF 23 mm FOR CAPS (7006-29B-2) |
LX-T5-287 | E26d GAUGE WITH REFERENCE DIAMETER OF 13,2 mm FOR CAPS (7006-29C-2) |
LX-T5-288 | E26d GAUGE WITH REFERENCE DIAMETER OF 10,4 mm FOR CAPS ON FINISHED LAMPS (7006-29D-1) |
LX-T5-289 | G5 DOUBLE ENDED GAUGE III. FOR A COMBINED PAIR OF LAMPHOLDERS FOR TESTING CONTACT-MAKING (7006-47B-4, IEC 60400) |
LX-T5-290 | G5 DOUBLE ENDED GAUGE IV. FOR A COMBINED PAIR OF LAMPHOLDERS FOR TESTING CONTACT-MAKING (7006-47B-4, IEC 60400) |
LX-T5-291 | G5 DOUBLE ENDED GAUGE V. FOR A COMBINED PAIR OF LAMPHOLDERS FOR TESTING CONTACT-MAKING (7006-47B-4, IEC 60400) |
LX-T5-292 | E26 "GO" GAUGE FOR LAMPHOLDERS (7006-25B-2) |
LX-T5-293 | E26 & E26d "NOT GO" GAUGE FOR LAMPHOLDERS (7006-26A-2) |
LX-T5-294 | E26d GAUGE FOR CHECKING THE RADIAL POSITION OF THE INTERMEDIATE CONTACT OF LAMPHOLDER(7006-29E-1) |
LX-T5-295 | E26d GAUGE A FOR TESTING THE RELATIVE POSITION OF THE CONTACT IN LAMPHOLDERS (7006-29F-2) |
LX-T5-296 | E26d GAUGE B FOR TESTING THE RELATIVE POSITION OF THE CONTACT IN LAMPHOLDERS (7006-29F-2) |
LX-T5-297 | E26d GAUGE FOR TESTING CONTACT-MAKING IN LAMPHOLDERS (7006-29G-3) |
LX-T5-298 | E26d GAUGE FOR TESTING CONTACT-MAKING IN METAL-SHELL PAPER-LINED LAMPHOLDERS (7006-29H-3) |
LX-T5-299 | E26d PLUG GAUGE FOR TESTING PROTECTION AGAINST ACCIDENTAL CONTACT IN LAMPHOLDERS (7006-29J-1) |
LX-T5-300 | E26d "GO" PLUG GAUGE FOR LAMPHOLDERS (7006-29K-1) |
LX-T5-301 | GAUGE 947 A1 |
LX-T5-302 | GAUGE 947 A2 |
LX-T5-303 | GAUGE 947 A3 |
LX-T5-304 | GAUGE 947 A4 |
LX-T5-305 | GAUGE 947 A5 |
LX-T5-306 | GAUGE 947 B6 |
LX-T5-307 | GAUGE 947 B7 |
LX-T5-308 | GAUGE 947 B8 |
LX-T5-309 | GAUGE 947 B9 |
LX-T5-31 | DUMMY FUSE LINK SET (4 pcs.) SIZE 00 |
LX-T5-310 | GAUGE 947 B10 |
LX-T5-311 | GAUGE 947 B11 |
LX-T5-312 | GAUGE 947 B12 |
LX-T5-313 | GAUGE 947 B13 |
LX-T5-314 | GAUGE 947 B14 |
LX-T5-315 | GAUGE 947 B15 |
LX-T5-316 | GAUGE 947 B16 |
LX-T5-317 | SET OF GAUGES 947 |
LX-T5-32 | DUMMY FUSE LINK SET (4 pcs.) SIZE 0 |
LX-T5-320 | VESSEL FOR TESTING HOB ELEMENTS AND HOTPLATES DIA. 110 (IEC 60335-2-6, Fig. 101, IEC 60335-2-9, Fig. 103) |
LX-T5-321 | VESSEL FOR TESTING HOB ELEMENTS AND HOTPLATES DIA. 145 (IEC 60335-2-6, Fig. 101, IEC 60335-2-9, Fig. 103) |
LX-T5-322 | VESSEL FOR TESTING HOB ELEMENTS AND HOTPLATES DIA. 180 (IEC 60335-2-6, Fig. 101, IEC 60335-2-9, Fig. 103) |
LX-T5-323 | VESSEL FOR TESTING HOB ELEMENTS AND HOTPLATES DIA. 220 (IEC 60335-2-6, Fig. 101, IEC 60335-2-9, Fig. 103) |
LX-T5-324 | VESSEL FOR TESTING HOB ELEMENTS AND HOTPLATES DIA. 300 (IEC 60335-2-6, Fig. 101, IEC 60335-2-9, Fig. 103) |
LX-T5-328 | GLASS VESSEL FOR MICROWAVE OVEN |
|
|
LX-T5-33 | DUMMY FUSE LINK SET (4 pcs.) SIZE 1 |
LX-T5-330 | LOADING WEIGHT 0.5 KG FOR REFRIGERATORS |
LX-T5-331 | LOADING WEIGHT 2.3 KG FOR REFRIGERATORS |
LX-T5-335 | ECCENTRIC WEIGHT FOR OVENS (IEC 60335-2-6, Fig. 103) |
LX-T5-336 | TEST ROD dia. 6, l 150 |
LX-T5-337 | SHORT TEST PROBE DIA. 12 |
LX-T5-338 | TEST ROD DIA. 40 WITH HEMILX-SPHERICAL END |
LX-T5-339 | TEST HEMILX-SPHE DIA. 100 |
LX-T5-34 | DUMMY FUSE LINK SET (4 pcs.) SIZE 2 |
LX-T5-340 | G5 PLUG GAUGE FOR LAMPHOLDERS FOR TESTING PROTECTION AGAINST ACCIDENTAL CONTACT (7006-47A-2) |
LX-T5-341 | G23 PLUG GAUGE "A" FOR CHECKING MAXIMUM INSERTION FORCE AND MAXIMUM WITHDRAW FORCE IN LAMPHOLDERS (7006-69A-1) |
LX-T5-342 | G23 and GX23 PLUG GAUGE "B" FOR CHECKING MAXIMUM INSERTION FORCE IN LAMPHOLDER (7006-69B-2) |
LX-T5-343 | G23 PLUG GAUGE "C" FOR CHECKING MINIMUM RETENTION FORCE IN LAMPHOLDERS |
LX-T5-344 | G13 DOUBLE ENDED GAUGE III. FOR A COMBINED PAIR OF LAMPHOLDERS FOR TESTING CONTACT-MAKING (7006-60B-4, IEC 60400) |
LX-T5-345 | G13 DOUBLE ENDED GAUGE IV. FOR A COMBINED PAIR OF LAMPHOLDERS FOR TESTING CONTACT-MAKING (7006-60B-4, IEC 60400) |
LX-T5-346 | G13 DOUBLE ENDED GAUGE V. FOR A COMBINED PAIR OF LAMPHOLDERS FOR TESTING CONTACT-MAKING (7006-60B-4, IEC 60400) |
LX-T5-347 | G5 TEST CAP (IEC 60400, Fig. 4) |
LX-T5-348 | G13 TEST CAP (IEC 60400, Fig. 4) |
LX-T5-35 | DUMMY FUSE LINK SET (4 pcs.) SIZE 3 |
LX-T5-350 | GO GAUGE FOR CONNECTORS TO STANDARD SHEET C1 (IEC 60320-1, FIG. 2) |
LX-T5-351 | GO GAUGE FOR CONNECTORS TO STANDARD SHEET C5 (IEC 60320-1, FIG. 4) |
LX-T5-352 | GO GAUGE FOR CONNECTORS TO STANDARD SHEET C7 (IEC 60320-1, FIG. 5) |
LX-T5-353 | GO GAUGE FOR SIDE-ENTRY CONNECTORS TO STANDARD SHEET C7 (IEC 60320-1, FIG. 5 bis) |
LX-T5-354 | NOT-GO GAUGE FOR CONNECTORS TO STANDARD SHEET C1 (IEC 60320-1, FIG. 6) |
LX-T5-355 | NOT-GO GAUGE FOR CONNECTORS TO STANDARD SHEETS C1, C5 AND C7 (IEC 60320-1, FIG. 7) |
LX-T5-356 | NOT-GO GAUGE FOR CONNECTORS TO STANDARD SHEETS C1 AND C7 (IEC 60320-1, FIG. 8) |
LX-T5-357 | NOT-GO GAUGE FOR APPLIANCE INLETS TO STANDARD SHEETS C8, C8A AND C8B (IEC 60320-1, F. 9) |
LX-T5-358 | GO GAUGE FOR CONNECTORS TO STANDARD SHEET C9 (IEC 60320-1, FIG. 9A) |
LX-T5-359 | NOT-GO GAUGE FOR CONNECTORS TO STANDARD SHEET C9 (IEC 60320-1, FIG. 9B) |
LX-T5-36 | DUMMY FUSE LINK SET (4 pcs.) SIZE 4 |
LX-T5-360 | GO GAUGE FOR APPLIANCE INLETS TO STANDARD SHEET C10 (IEC 60320-1, FIG. 9C) |
LX-T5-361 | GO GAUGE FOR CONNECTORS TO STANDARD SHEET C17 (IEC 60320-1, FIG. 9K) |
LX-T5-362 | GO GAUGE FOR CONNECTORS TO STANDARD SHEET C19 (IEC 60320-1, FIG. 9L) |
LX-T5-363 | GO GAUGE FOR APPLIANCE INLETS TO STANDARD SHEETS C20 AND C24 (IEC 60320-1, FIG. 9M) |
LX-T5-364 | GO GAUGE FOR CONNECTORS TO STANDARD SHEET C21 (IEC 60320-1, FIG. 9N) |
LX-T5-365 | GO GAUGE FOR APPLIANCE INLETS TO STANDARD SHEET C22 (IEC 60320-1, FIG. 9P) |
LX-T5-366 | GO GAUGE FOR CONNECTORS TO STANDARD SHEET C23 (IEC 60320-1, FIG. 9Q) |
LX-T5-37 | DUMMY FUSE LINK SET (4 pcs.) SIZE 4a |
LX-T5-370 | VESSEL FOR TESTING INDUCTION HOTPLATES DIA. 110 (IEC 60335-2-6, Fig. 102, IEC 60335-2-9, Fig. 104) |
LX-T5-371 | VESSEL FOR TESTING INDUCTION HOTPLATES DIA. 145 (IEC 60335-2-6, Fig. 102, IEC 60335-2-9, Fig. 104) |
LX-T5-372 | VESSEL FOR TESTING INDUCTION HOTPLATES DIA. 180 (IEC 60335-2-6, Fig. 102, IEC 60335-2-9, Fig. 104) |
LX-T5-373 | VESSEL FOR TESTING INDUCTION HOTPLATES DIA. 220 (IEC 60335-2-6, Fig. 102, IEC 60335-2-9, Fig. 104) |
LX-T5-374 | VESSEL FOR TESTING INDUCTION HOTPLATES DIA. 300 (IEC 60335-2-6, Fig. 102, IEC 60335-2-9, Fig. 104) |
LX-T5-375 | VESSEL FOR TESTING INDUCTION HOTPLATES DIA. 210 (IEC 60335-2-6, Fig. 102, IEC 60335-2-9, Fig. 104) |
LX-T5-376 | VESSEL FOR TESTING INDUCTION HOTPLATES DIA. 270 (IEC 60335-2-6, Fig. 102, IEC 60335-2-9, Fig. 104) |
LX-T5-37X | VESSELS FOR TESTING INDUCTION HOTPLATES |
LX-T5-380 | "GO" AND "NOT GO" GAUGE FOR STARTERS (IEC 155 fig. 6) |
LX-T5-381 | "NOT GO" GAUGE FOR STARTERS (IEC 155 fig. 7) |
LX-T5-382 | "GO" GAUGE FOR STARTERS (IEC 155 fig. 8) |
LX-T5-383 | "GO" GAUGE FOR STARTERS FOR CLASS II LUMINAIRES (IEC 155 fig. B.2) |
LX-T5-400 | "GO" GAUGE FOR E27 CAPS ON FINISHED LAMPS (7006-27B-1) |
LX-T5-401 | "GO" GAUGE FOR E14 CAPS ON FINISHED LAMPS (7006-27F-1) |
LX-T5-402 | "NOT GO" GAUGE FOR E27 CAPS ON FINISHED LAMPS (7006-28A-1) |
LX-T5-403 | "NOT GO" GAUGE FOR E14 CAPS ON FINISHED LAMPS (7006-28B-1) |
LX-T5-404 | "GO" GAUGE FOR DIMENSION "S1" OF E27 CAPS ON FINISHED LAMPS (7006-27C-1) |
LX-T5-405 | "GO" GAUGE FOR DIMENSION "S1" OF E14 CAPS ON FINISHED LAMPS (7006-27G-1) |
LX-T5-406 | GAUGE FOR FINISHED LAMPS FITTED WITH E27 CAPS FOR TESTING CONTACT MAKING (7006-50-1) |
LX-T5-407 | GAUGE FOR FINISHED LAMPS FITTED WITH E14 CAPS FOR TESTING CONTACT MAKING (7006-54-2) |
LX-T5-41 | RIGID TEST FINGER (IEC 61032, F. 7, TEST PROBE 11) |
LX-T5-411 | GAUGE FOR E27 CAPS ON FINISHED LAMPS FOR TESTING PROT. AGAINST ACC. CONTACT (7006-51A-2) |
LX-T5-412 | GAUGE FOR FINISHED LAMPS FITTED WITH E14 CAPS FOR TESTING PROT. AGAINST ACC. CONTACT (7006-55-2) |
LX-T5-413 | GAUGE FOR E27/51x39 CAPS ON FINISHED LAMPS FOR TESTING PROT. AGAINST ACC. CONTACT (7006-51-2) |
LX-T5-414 | GAUGE FOR E27 CAPS ON FINISHED LAMPS FOR TESTING PROT. AGAINST ACC. CONTACT DURING INSERTION (7006-51A-2) |
LX-T5-415 | "NOT GO" GAUGE FOR B15 CAPS ON FINISHED LAMPS (7006-10-8) |
LX-T5-416 | "NOT GO" GAUGE FOR B22 CAPS ON FINISHED LAMPS (7006-10-8) |
LX-T5-417 | "GO" GAUGE FOR B15 CAPS ON FINISHED LAMPS (7006-11-8) |
LX-T5-418 | "GO" GAUGE FOR B22 CAPS ON FINISHED LAMPS (7006-11-8) |
LX-T5-419 | GAUGE B15d FOR TESTING THE INSERTION OF CAPS IN LAMPHOLDERS (7006-4A-2) |
LX-T5-42 | RIGID TEST FINGER WITH FORCE METER 50 N |
LX-T5-420 | GAUGE B22d FOR TESTING THE INSERTION OF CAPS IN LAMPHOLDERS (7006-4A-2) |
LX-T5-421 | GAUGE FOR TESTING THE RETENTION OF B15d CAPS IN THE HOLDER (7006-4B-1) |
LX-T5-422 | GAUGE FOR TESTING THE RETENTION OF B22d CAPS IN THE HOLDER (7006-4B-1) |
LX-T5-43 | RIGID TEST FINGER WITH FORCE METER 100 N |
LX-T5-430 | E27 HOLDER FOR TORQUE TEST ON LAMPS WITH SCREW CAPS (IEC 60968 F. 3) |
LX-T5-431 | E26 HOLDER FOR TORQUE TEST ON LAMPS WITH SCREW CAPS (IEC 60968 F. 3, 60432-1 F. C.2) |
LX-T5-432 | B22 HOLDER FOR TORQUE TEST ON LAMPS WITH BAYONET CAPS (IEC 60968 F. 3, 60432-1 F. C.1) |
LX-T5-433 | E14 HOLDER FOR TORQUE TEST ON LAMPS WITH SCREW CAPS (IEC 60968 F. 3, 60432-1 F. C.2) |
LX-T5-438 | "GO" GAUGE FOR CAPS E26, E26/50x39, E26/51x39 & E26d (7006-27D-3) |
LX-T5-440 | B22d GAUGE FOR CHECKING CONTACT POSITION AND CONTACT FORCE IN BAYONET LAMPHOLDERS (7006-15A-2) |
LX-T5-441 | BY22d GAUGE FOR CHECKING CONTACT POSITION AND CONTACT FORCE IN BAYONET LAMPHOLDERS (7006-15A-2) |
LX-T5-442 | B15d GAUGE FOR CHECKING CONTACT POSITION AND CONTACT FORCE IN BAYONET LAMPHOLDERS (7006-15B-1) |
LX-T5-443 | B15d GAUGE FOR THE SLOTS IN LAMHOLDERS (7006-13-5) |
LX-T5-444 | B22d, B22d-3 & BY22d GAUGE FOR THE SLOTS IN LAMHOLDERS (7006-13-5) |
LX-T5-445 | B15d SUPPLEMENTARY "GO" GAUGE FOR LAMPHOLDERS (7006-12C-2) |
LX-T5-446 | B15 "NOT GO"/RETENTION GAUGE FOR LAMPHOLDERS (7006-12D-2) |
LX-T5-447 | B22d SUPPLEMENTARY "GO" GAUGE FOR LAMPHOLDERS (7006-12A-2) |
LX-T5-448 | BY22d SUPPLEMENTARY "GO" GAUGE FOR LAMPHOLDERS (7006-12A-2) |
LX-T5-449 | B22 "NOT GO"/RETENTION GAUGE FOR LAMPHOLDERS (7006-12B-2) |
LX-T5-451 | 28x2 "GO" AND "NOT GO" FOR BARREL THREAD OF SHADE HOLDER RINGS (60399-IEC-03-1, 60238) |
LX-T5-452 | 40x2,5 "GO" AND "NOT GO" FOR BARREL THREAD OF SHADE HOLDER RINGS (60399-IEC-03-1, 60238) |
LX-T5-453 | 35x2,74 "GO" AND "NOT GO" FOR BARREL THREAD OF SHADE HOLDER RINGS (60399-IEC-03-1, 60238) |
LX-T5-454 | 45x2,74 "GO" AND "NOT GO" FOR BARREL THREAD OF SHADE HOLDER RINGS (60399-IEC-03-1, 60238) |
LX-T5-455 | 20,8x2 "GO" AND "NOT GO" FOR BARREL THREAD OF SHADE HOLDER RINGS (60399-IEC-03-1, 60238) |
LX-T5-457 | PLUG GAUGE FOR LAMPHOLDERS BY22d (Sh. 7006-17B-1) |
LX-T5-458 | GAUGE FOR CHECKING CONTACT POSITION AND CONTACT FORCE IN BAYONET LAMPHOLDERS B22d-3 (90/135deg) (Sh. 7006-15-7) |
LX-T5-459 | 20,8x2 "GO" GAUGE FOR BARREL THREAD OF LAMPHOLDERS WITH SHADE HOLDER RING (60399-IEC-04-1, 60238) |
LX-T5-46 | TEST PIN DIA. 1 x 20 mm (Fig. 1, BS 1363-2) |
LX-T5-460 | 28x2 "GO" GE FOR BARREL THREAD OF LAMPHOLDERS WITH SHADE HOLDER RING (60399-IEC-04-1, 60238) |
LX-T5-461 | 40x2,5 "GO" GE FOR BARREL THREAD OF LAMPHOLDERS WITH SHADE HOLDER RING (60399-IEC-04-1, 60238) |
LX-T5-462 | 35x2,74 "GO" GE FOR BARREL THREAD OF LAMPHOLDERS WITH SHADE HOLDER RING (60399-IEC-04-1, 60238) |
LX-T5-463 | 45x2,74 "GO" GE FOR BARREL THREAD OF LAMPHOLDERS WITH SHADE HOLDER RING (60399-IEC-04-1, 60238) |
LX-T5-464 | 28x2 "NOT GO" GE FOR BARREL THREAD OF LAMPHOLDERS WITH SHADE HOLDER RING (60399-IEC-04-1, 60238) |
LX-T5-465 | 40x2,5 "NOT GO" GE FOR BARREL THREAD OF LAMPHOLDERS WITH SHADE HOLDER RING (60399-IEC-04-1, 60238) |
LX-T5-466 | 35x2,74 "NOT GO" GE FOR BARREL THREAD OF LAMPHOLDERS WITH SHADE HOLDER RING (60399-IEC-04-1, 60238) |
LX-T5-467 | 45x2,74 "NOT GO" GE FOR BARREL THREAD OF LAMPHOLDERS WITH SHADE HOLDER RING (60399-IEC-04-1, 60238) |
LX-T5-468 | GX24 GAUGE "A" FOR LAMPHOLDER (7006-78A-5) |
LX-T5-469 | GX24 GAUGE "C" FOR LAMPHOLDER (7006-78C-5) |
LX-T5-47 | TEST PIN DIA.3-DIA.4, l=15 (IEC 61032, F. 9, TEST PROBE 13) |
LX-T5-470 | TEST CAP FOR THE TEST OF CLAUSE 13 FOR LAMPHOLDERS GX10q AND GY10q (IEC 60400 F. 27) |
LX-T5-471 | TEST CAP FOR THE TEST OF 17.1 FOR LAMPHOLDERS GX10q (IEC 60400 F. 33) |
LX-T5-472 | PLUG GAUGE "B" FOR CHECKING MINIMUM CONTACT FORCE IN LAMPHOLDER GY10q (Sh. 7006-85C-1) |
LX-T5-473 | "GO" GAUGE FOR LAMPHOLDER GY10q (Sh. 7006-85B-2) |
LX-T5-474 | "GO" GAUGE FOR LAMPHOLDER GX10q (Sh. 7006-84C-2) |
LX-T5-475 | PLUG GAUGE "B" FOR CHECKING MINIMUM CONTACT FORCE IN LAMPHOLDERS GX10q TYPE A AND MINIMUM RETENTION FORCE IN LAMPHOLDERS TYPE B (Sh. 7006-84D-1) |
LX-T5-476 | PLUG GAUGE LAMPHOLDER BA21 (Sh. 7006-12-8) |
LX-T5-477 | PLUG GAUGE LAMPHOLDER B15 (Sh. 7006-12-8) |
LX-T5-478 | PLUG GAUGE LAMPHOLDER B22 (Sh. 7006-12-8) |
LX-T5-479 | "GO" AND "NOT GO" PLUG GAUGE FOR BAYONET LAMPHOLDER B22d-3 (Sh. 7006-20-4) |
LX-T5-48 | TEST PIN DIA. 4 x 100 mm |
LX-T5-480 | 20,8x2 "NOT GO" GE FOR BARREL THREAD OF LAMPHOLDERS WITH SHADE HOLDER RING (60399-IEC-04-1, 60238) |
LX-T5-481 | G24, GX24 & GY24 "NOT GO" GAUGE "F" FOR CHECKING NON-INTERCHANGEABILITY OF CAPS IN LAMPHOLDERS (7006-78F-6 Fig. 1) |
LX-T5-482 | G24, GX24 & GY24 "NOT GO" GAUGE "F" FOR CHECKING NON-INTERCHANGEABILITY OF CAPS IN LAMPHOLDERS (7006-78F-6 Fig. 2) |
LX-T5-483 | G24, GX24 & GY24 "NOT GO" GAUGE "F" FOR CHECKING NON-INTERCHANGEABILITY OF CAPS IN LAMPHOLDERS (7006-78F-6 Fig. 3) |
LX-T5-484 | G24, GX24 & GY24 "NOT GO" GAUGE "F" FOR CHECKING NON-INTERCHANGEABILITY OF CAPS IN LAMPHOLDERS (7006-78F-6 Fig. 4) |
LX-T5-485 | G24, GX24 "NOT GO" GAUGE "F" FOR CHECKING NON-INTERCHANGEABILITY OF CAPS IN LAMPHOLDERS (7006-78F-6 Fig. 5) |
LX-T5-486 | G24, GX24 "NOT GO" GAUGE "F" FOR CHECKING NON-INTERCHANGEABILITY OF CAPS IN LAMPHOLDERS (7006-78F-6 Fig. 6) |
LX-T5-487 | G24, GX24 "NOT GO" GAUGE "F" FOR CHECKING NON-INTERCHANGEABILITY OF CAPS IN LAMPHOLDERS (7006-78F-6 Fig. 7) |
LX-T5-488 | GO AND NOT GO GAUGE FOR CAPS G24, GX24 & GY24 (Sh. 7006-78-5, Fig. 1) |
LX-T5-489 | GO AND NOT GO GAUGE FOR CAPS G24, GX24 & GY24 (Sh. 7006-78-5, Fig. 2) |
LX-T5-49 | LONG TEST PIN DIA.3-DIA.4, l=50 |
LX-T5-490 | GO AND NOT GO GAUGE FOR CAPS G24, GX24 & GY24 (Sh. 7006-78-5, Fig. 3) |
LX-T5-491 | GO AND NOT GO GAUGE FOR CAPS G24, GX24 & GY24 (Sh. 7006-78-5, Fig. 4) |
LX-T5-492 | GO AND NOT GO GAUGE FOR CAPS G24q-5 & GX24q-5 (Sh. 7006-78-5, Fig. 1) |
LX-T5-493 | G5.3 "GO" GAUGE FOR LAMHOLDERS (7006-73A-1) |
LX-T5-494 | GX5.3 "GO" GAUGE FOR LAMPHOLDERS (7006-73D-3) |
LX-T5-495 | GY5.3 "GO" GAUGE FOR LAMPHOLDERS (7006-73E-3) |
LX-T5-496 | GY5.3 SINGLE PIN GAUGE FOR CHECKING MINIMUM RETENTION FORCE OF CONTACTS IN LAMPHOLDERS (7006-73J-1) |
LX-T5-497 | GZ10 "GO" AND "NOT GO" GAUGE FOR BASES (7006-120-1) |
LX-T5-498 | G5 DOUBLE ENDED GAUGE V. FOR A COMBINED PAIR OF LAMPHOLDERS FOR TESTING CONTACT-MAKING (7006-47B-4) (Change E=2.44 D=4.4 mm) |
LX-T5-499 | G13 DOUBLE ENDED GAUGE V. FOR A COMBINED PAIR OF LAMPHOLDERS FOR TESTING CONTACT-MAKING (7006-60B-4) (Change E=2.44 D = 12.35 mm) |
LX-T5-50 | TEST PROBE DIA. 30 x 80 mm (IEC 61032, F. 9, TEST PROBE 41) |
LX-T5-51 | RIGID STEEL WIRE DIA. 1 WITH HANDLE & STOP LX-SPHERE (IEC 61032 - Test probe D) |
LX-T5-52 | RIGID STEEL ROD DIA. 2,5 WITH HANDLE & STOP LX-SPHERE (IEC 61032 - Test probe C) |
LX-T5-534 | GU10 "GO" AND "NOT GO" GAUGE FOR BASES (7006-121-1) |
LX-T5-541 | R7s "GO" GAUGE FOR A COMBINED PAIR OF LAMPHOLDERS Z=118mm (7006-62-4) |
LX-T5-542 | R7s "GO" GAUGE FOR A COMBINED PAIR OF LAMPHOLDERS Z=189mm (7006-62-4) |
LX-T5-543 | R7s "GO" GAUGE FOR A COMBINED PAIR OF LAMPHOLDERS Z=254mm (7006-62-4) |
LX-T5-544 | R7s "GO" GAUGE FOR A COMBINED PAIR OF LAMPHOLDERS Z=333mm (7006-62-4) |
LX-T5-545 | SINGLE PIN GAUGE "E" FOR CHECKING MINIMUM RETENTION FORCE OF CONTACTS IN LAMPHOLDERS G5, 2G(X)7, 2G10, 2G11, G13, G(X)23, G(X)(Y)24, G(X)(Y)32 (7006-69E-5) |
LX-T5-546 | G5 "GO" AND "NO GO" GAUGE FOR UNMOUNTED BI-BIN CAP (7006-46-3) |
LX-T5-547 | G13 "GO" AND "NO GO" GAUGE FOR UNMOUNTED BI-BIN CAP (7006-44-4) |
LX-T5-548 | G6.35, GX6.35 & GZ6.35 "GO" AND "NOT GO" GAUGE FOR BASES (7006-61-5) |
LX-T5-549 | GY6.35 "GO" AND "NOT GO" GAUGE FOR BASES (7006-61-5) |
LX-T5-55 | TEST PIN DIA. 2 x 100 mm |
LX-T5-550 | G4 GAUGE A - "GO" AND "NOT GO" GAUGE FOR PINS OF BI-PIN LAMP BASES (7006-72-1) |
LX-T5-551 | G4 GAUGE B - "GO" GAUGE FOR BASE OF BI-PIN LAMP BASES (7006-72-1) |
LX-T5-552 | G5.3 GAUGE FOR BI-PIN CAP ON FINISHED LAMPS (7006-73-1) |
LX-T5-553 | G5.3 "GO" GAUGE FOR BASE (7006-126-1) |
LX-T5-554 | GU10 "GO" AND "NOT GO" GAUGE FOR BASES (7006-121-1) isti kot LX-T5-534 |
LX-T5-555 | GR8&GR10q GO GAUGE FOR CHECKING THE PINS OF CAPS ON FINISHED LAMPS (7006-68E-1) |
LX-T5-556 | GR8&GR10q GO AND NOT GO GAUGE FOR CHECKING THE PINS OF CAPS (7006-68F-1) |
LX-T5-557 | GR10q GO GAUGE FOR UNMOUNTED CAPS (7006-77-2) |
LX-T5-558 | GR10q GAUGE FOR CAPS TO ENSURE ENTRY OF MAXIMUM LAMPHOLDERS AND TO CHECK PIN LX-SPACING AND LENGTH (7006-77A-2) |
LX-T5-559 | GX10q GO GAUGE FOR CAPS ON FINISHED LAMPS (7006-84-2) |
LX-T5-56 | TEST HOOK (IEC 60065, Figure 4) |
LX-T5-560 | GX10q NOT GO GAUGE "A" FOR CAPS ON FINISHED LAMPS (7006-84A-1) |
LX-T5-561 | GX10q NOT GO GAUGE "B" FOR CAPS ON FINISHED LAMPS (7006-84B-1) |
LX-T5-562 | GY10q GO GAUGE FOR CAPS ON FINISHED LAMPS (7006-85-2) |
LX-T5-563 | GY10q NOT GO GAUGE "A" FOR CAPS ON FINISHED LAMPS (7006-85A-1) |
LX-T5-564 | G13 HEATED TEST CAP A FOR TESTING OF RESISTANCE TO HEAT OF LAMPHOLDERS WITH T MARKING (IEC 60400 Fig. 9) |
LX-T5-565 | G13 HEATED TEST CAP B FOR TESTING OF RESISTANCE TO HEAT OF LAMPHOLDERS WITH T MARKING (IEC 60400 Fig. 9) |
LX-T5-566 | G5 HEATED TEST CAP FOR TESTING OF RESISTANCE TO HEAT OF LAMPHOLDERS WITH T MARKING (IEC 60400 Fig. 9a) |
LX-T5-568 | SET OF GAUGES A1-A16 (IEC 60947-1, Fig. 2) |
LX-T5-569 | SET OF GAUGES B1-B16 (IEC 60947-1, Fig. 2) |
LX-T5-571 | GAUGE FOR TESTING MAX. WITHDRAWAL FORCE OF PLUG 2P AC 250V 2,5A (DIN VDE 0620-1 Fig.16d) |
LX-T5-572 | GAUGE L1 FOR TESTING SOCKET OUTLETS (DIN 49 440 - L1) |
LX-T5-573 | GAUGE L2 FOR TESTING SOCKET OUTLETS (DIN 49 440 - L2) |
LX-T5-574 | RING GAUGE DIN 49 441 - L1 |
LX-T5-575 | RING GAUGE DIN 49 441 - L2 |
LX-T5-577 | GAUGE 14 (DIN VDE 0620-1) |
LX-T5-578 | GAUGE 16A (DIN VDE 0620-1) |
LX-T5-579 | E14 HOLDER FOR TORSION TEST ON LAMPS WITH SCREW CAPS (IEC 60968, Fig. 2) |
LX-T5-58 | TEST PIN DIA. 1 x 100 mm |
LX-T5-580 | E27 HOLDER FOR TORSION TEST ON LAMPS WITH SCREW CAPS (IEC 60968, Fig. 2) |
LX-T5-581 | B15 HOLDER FOR TORQUE TEST ON LAMPS WITH BAYONET CAPS (IEC 60968, Fig. 3) |
LX-T5-582 | B22 HOLDER FOR TORQUE TEST ON LAMPS WITH BAYONET CAPS (IEC 60968, Fig. 3) |
LX-T5-583 | GX10q-1 GO GAUGE FOR KEYS OF CAPS ON FINISHED LAMPS (7006-84E-1) |
LX-T5-584 | GX10q-2 GO GAUGE FOR KEYS OF CAPS ON FINISHED LAMPS (7006-84E-1) |
LX-T5-585 | GX10q-3 GO GAUGE FOR KEYS OF CAPS ON FINISHED LAMPS (7006-84E-1) |
LX-T5-586 | GX10q-4 GO GAUGE FOR KEYS OF CAPS ON FINISHED LAMPS (7006-84E-1) |
LX-T5-587 | GX10q-5 GO GAUGE FOR KEYS OF CAPS ON FINISHED LAMPS (7006-84E-1) |
LX-T5-588 | GX10q-6 GO GAUGE FOR KEYS OF CAPS ON FINISHED LAMPS (7006-84E-1) |
LX-T5-589 | GY10q-1 GO GAUGE FOR KEYS OF CAPS ON FINISHED LAMPS (7006-85D-1) |
LX-T5-59 | TEST PROBE DIA. 12 (IEC 60950, Fig. 2C) |
LX-T5-590 | GY10q-2 GO GAUGE FOR KEYS OF CAPS ON FINISHED LAMPS (7006-85D-1) |
LX-T5-591 | GY10q-3 GO GAUGE FOR KEYS OF CAPS ON FINISHED LAMPS (7006-85D-1) |
LX-T5-592 | GY10q-4 GO GAUGE FOR KEYS OF CAPS ON FINISHED LAMPS (7006-85D-1) |
LX-T5-593 | GY10q-5 GO GAUGE FOR KEYS OF CAPS ON FINISHED LAMPS (7006-85D-1) |
LX-T5-594 | GY10q-6 GO GAUGE FOR KEYS OF CAPS ON FINISHED LAMPS (7006-85D-1) |
LX-T5-595 | GAUGE FOR CHECKING SIDE CONTACTS (F. 43 - DIN VDE 0620-1) |
LX-T5-596 | "GO" GAUGE A FOR THE CONTACTS OF LAMPHOLDERS G10q, GX10q, GY10q & GZ10q (7006-79A-2) |
LX-T5-597 | "GO" GAUGE B FOR THE CONTACTS OF LAMPHOLDERS G10q, GX10q, GY10q & GZ10q (7006-79A-2) |
LX-T5-598 | CONTACT MAKING GAUGE FOR LAMPHOLDERS G10q, GX10q, GY10q (7006-79B-1) |
LX-T5-60 | STRAIGHT PROBE DIA. 38 (UL 153, Fig. 1) |
LX-T5-600 | APPLIANCE INLET GAUGE FOR MAX. WITHDRAWAL FORCE CHECKING - C2 (IEC 60320-1, Cl. 16) |
LX-T5-601 | APPLIANCE INLET GAUGE FOR MAX. WITHDRAWAL FORCE CHECKING - C6 (IEC 60320-1, Cl. 16) |
LX-T5-602 | APPLIANCE INLET GAUGE FOR MAX. WITHDRAWAL FORCE CHECKING - C8 (IEC 60320-1, Cl. 16) |
LX-T5-603 | APPLIANCE INLET GAUGE FOR MAX. WITHDRAWAL FORCE CHECKING - C10 (IEC 60320-1, Cl. 16) |
LX-T5-604 | APPLIANCE INLET GAUGE FOR MAX. WITHDRAWAL FORCE CHECKING - C18 (IEC 60320-1, Cl. 16) |
LX-T5-605 | APPLIANCE INLET GAUGE FOR MAX. WITHDRAWAL FORCE CHECKING - C20 (IEC 60320-1, Cl. 16) |
LX-T5-606 | APPLIANCE INLET GAUGE FOR MAX. WITHDRAWAL FORCE CHECKING - C22 (IEC 60320-1, Cl. 16) |
LX-T5-607 | APPLIANCE INLET GAUGE FOR MAX. WITHDRAWAL FORCE CHECKING - C24 (IEC 60320-1, Cl. 16) |
LX-T5-61 | TEST LX-SPHERE DIA. 50, 0,51 kg |
LX-T5-611 | GAUGE FOR THE VERIFICATION OF THE MINIMUM WITHDRAWAL FORCE 1.5 N - C1, C5 and C7 (IEC 60320-1, Cl. 16) |
LX-T5-612 | GAUGE FOR THE VERIFICATION OF THE MINIMUM WITHDRAWAL FORCE 1.5 N - C5 (LONG) (IEC 60320-1, Cl. 16) |
LX-T5-613 | GAUGE FOR THE VERIFICATION OF THE MINIMUM WITHDRAWAL FORCE 1.5 N - C9, C13, C15, C15A, AND C17 (IEC 60320-1, Cl. 16) |
LX-T5-614 | GAUGE FOR THE VERIFICATION OF THE MINIMUM WITHDRAWAL FORCE 1.5 N - C13, C15 AND C15A (LONG) (IEC 60320-1, Cl. 16) |
LX-T5-615 | GAUGE FOR THE VERIFICATION OF THE MINIMUM WITHDRAWAL FORCE 2 N - C19, C21 AND C23 (IEC 60320-1, Cl. 16) |
LX-T5-616 | GAUGE FOR THE VERIFICATION OF THE MINIMUM WITHDRAWAL FORCE 2 N - C19, AND C21 (LONG) (IEC 60320-1, Cl. 16) |
LX-T5-62 | RIGID LX-SPHERE DIA. 12.5 |
LX-T5-620 | GO GAUGE FOR APPLIANCE OUTLETS TO STANDARD SHEET F (IEC 320-2-2, FIG. 101) |
LX-T5-621 | GO GAUGE FOR APPLIANCE OUTLETS TO STANDARD SHEET H (IEC 320-2-2, FIG. 102) |
LX-T5-622 | GO GAUGE FOR APPLIANCE OUTLETS TO STANDARD SHEET J (IEC 320-2-2, FIG. 103) |
LX-T5-623 | GO GAUGE FOR APPLIANCE OUTLETS TO STANDARD SHEET L (IEC 320-2-2, FIG. 104) |
LX-T5-63 | TEST LX-SPHERE 0,5 kg (IEC 60950-1) |
LX-T5-630 | GO GAUGE FOR STARTERS FOR CLASS II LUMINAIRES (Fig. B2, IEC 155) |
LX-T5-631 | GO GAUGE FOR BI-PIN CAP ON FINISHED LAMPS G5 (Sh. 7006-46A-3) |
LX-T5-632 | GO GAUGE FOR BI-PIN CAP ON FINISHED LAMPS G13 (Sh. 7006-45-4) |
LX-T5-633 | GO AND NOT GO GAUGE FOR CAPS ON FINISHED LAMPS 2G7 & 2GX7 (Sh. 7006-102-1) |
LX-T5-638 | GO GAUGE FOR CAPS ON FINISHED LAMPS 2G11 (Sh. 7006-82-1) |
LX-T5-639 | GO GAUGE FOR CAPS ON FINISHED LAMPS G10q, GX10q, GY10q, GZ10q (Sh. 7006-79-2) |
LX-T5-64 | TEST LX-SPHERE DIA. 40 (IEC 60950-1, 60065) |
LX-T5-640 | GO GAUGE FOR SINGLE-PIN CAP Fa8 (Sh. 7006-40-1) |
LX-T5-641 | NOT GO GAUGE FOR SINGLE-PIN CAP Fa8 (Sh. 7006-40A-1) |
LX-T5-642 | GO AND NOT GO GAUGE FOR SINGLE-PIN CAP ON FINISHED LAMPS Fa6 (Sh. 7006-41-2) |
LX-T5-643 | GO GAUGE FOR CAPS 2G13-41 (Sh. 7006-33-2) |
LX-T5-644 | GO GAUGE FOR CAPS 2G13-56 (Sh. 7006-33-2) |
LX-T5-645 | GO GAUGE FOR CAPS 2G13-92 (Sh. 7006-33-2) |
LX-T5-646 | GO GAUGE FOR CAPS 2G13-152 (Sh. 7006-33-2) |
LX-T5-647 | GO AND NOT GO GAUGE FOR RECESSED DOUBLE COONTACT CAP R17d ON FINISHED LAMPS (Sh. 7006-57-3) |
LX-T5-650 | GAUGE FOR THE VERIFICATION OF MAXIMUM WITHDRAWAL FORCE (F. 101, IEC 60884-2-4) |
LX-T5-651 | GAUGE FOR THE VERIFICATION OF MINIMUM WITHDRAWAL FORCE (F. 102, IEC 60884-2-4) |
LX-T5-652 | GAUGE C1 FOR SIZE OF ENTRY HOLES FOR PLUG PINS DIA. 5,8 MM (F. 1, CEE 7, VDE0620-1 Gauge 1) |
LX-T5-653 | GAUGE C1 FOR SIZE OF ENTRY HOLES FOR PLUG PINS DIA. 6 MM (F. 1, CEE 7, VDE0620-1 Gauge 1) |
LX-T5-654 | GAUGE C2A FOR MINIMUM OPENING OF CONTACT TUBES, 400 G (F. 2 CEE 7) |
LX-T5-655 | GAUGE C2B FOR MINIMUM OPENING OF CONTACT TUBES, 400 G (F. 2 CEE 7) |
LX-T5-656 | GAUGE C3 FOR ACCEPTANCE OF TWO-POLE PLUGS (F. 3 CEE 7, VDE0620-1 Gauge 3) |
LX-T5-657 | GAUGE C4 FOR ACCEPTANCE OF TWO-POLE PLUGS WITH SIDE EARTHING-CONTACTS (F. 4 CEE 7, VDE0620-1 Gauge 4) |
LX-T5-658 | GAUGE C6A FOR FIXING HOLES OR SLOTS (F. 6 CEE 7) |
LX-T5-659 | GAUGE C6B FOR FIXING HOLES OR SLOTS (F. 6 CEE 7) |
LX-T5-66 | RIGID TEST LX-SPHERE WITH GUARD DIA. 50 |
LX-T5-660 | GAUGE C7A FOR DISTANCE TO POINT OF FIRST CONTACT (F. 7 CEE 7, VDE0620-1 Gauge 5) |
LX-T5-661 | GAUGE C7B FOR DISTANCE TO POINT OF FIRST CONTACT (F. 7 CEE 7, VDE0620-1 Gauge 5) |
LX-T5-662 | GAUGE C7C FOR DISTANCE TO POINT OF FIRST CONTACT (F. 7 CEE 7, VDE0620-1 Gauge 5) |
LX-T5-663 | GAUGE C7D FOR DISTANCE TO POINT OF FIRST CONTACT (F. 7 CEE 7, VDE0620-1 Gauge 5) |
LX-T5-664 | GAUGE C8 FOR WIRING CHANNEL (F. 8 CEE 7) |
LX-T5-665 | "GO" GAUGE C9A FOR PIN DIAMETER (Fig. 9 CEE 7; EN 50075, Fig. 1, VDE0620-1 Gauge 6) |
LX-T5-666 | "NOT GO" GAUGE C9A FOR PIN DIAMETER (Fig. 9 CEE 7; EN 50075, Fig. 1, VDE0620-1 Gauge 6) |
LX-T5-667 | "GO" GAUGE C9B FOR PIN DIAMETER (F. 9 CEE 7, VDE0620-1 Gauge 6) |
LX-T5-668 | "NOT GO" GAUGE C9B FOR PIN DIAMETER (F. 9 CEE 7, VDE0620-1 Gauge 6) |
LX-T5-669 | GAUGE C10A FOR PIN LX-SPACING (F. 10 CEE 7, VDE0620-1 Gauge 7) |
LX-T5-67 | DYNAMOMETER 20 N |
LX-T5-670 | GAUGE C10B FOR PIN LX-SPACING (F. 10 CEE 7, VDE0620-1 Gauge 7) |
LX-T5-671 | GAUGE C11 FOR MAXIMUM OPENING OF CONTACT TUBES (F. 11 CEE 7, VDE0620-1 Gauge 8) |
LX-T5-672 | GAUGE C12 FOR INTERCHANGEABILITY (F. 12 CEE 7, VDE0620-1 Gauge 9) |
LX-T5-673 | GAUGE FOR INTERCHANGEABILITY (F. 13 CEE 7; EN 50075, Fig. 2) |
LX-T5-674 | GAUGE FOR DIMENSIONS OF MOUNTING BOXES (F. 14 CEE 7) |
LX-T5-675 | GAUGE FOR NON-INTERCHANGEABILITY WITH TWO-POLE PLUGS WITH EARTHING CONTACTS (F. 15 CEE 7) |
LX-T5-676 | GAUGE FOR NON-ACCEPTANCE OF TWO-POLE PLUGS WITHOUT EARTHING CONTACT (F. 16 CEE 7, VDE0620-1 Gauge 11) |
LX-T5-677 | GAUGE FOR CHECKING IMPOSSIBILITY OF SINGLE-POLE INSERTION OF PLUGS (F. 18 CEE 7, VDE0620-1 Gauge 10) |
LX-T5-678 | GAUGE A FOR CHECKING IMPOSSIBILITY OF SINGLE-POLE INSERTION OF PLUGS INTO SOCKET OUTLETS. 250&nbLX-SP;G (F. 19 CEE 7 ) |
LX-T5-679 | GAUGE B FOR CHECKING IMPOSSIBILITY OF SINGLE-POLE INSERTION OF PLUGS INTO SOCKET OUTLETS. 250&nbLX-SP;G (F. 19 CEE 7, VDE0620-1 GAUGE 12) |
LX-T5-68 | DYNAMOMETER 50N |
LX-T5-680 | GAUGE A FOR CHECKING IMPOSSIBILITY OF SINGLE-POLE INSERTION OF PLUGS INTO SOCKET OUTLETS. 1000&nbLX-SP;G (F. 19 CEE 7 ) |
LX-T5-681 | GAUGE B FOR CHECKING IMPOSSIBILITY OF SINGLE-POLE INSERTION OF PLUGS INTO SOCKET OUTLETS. 1000&nbLX-SP;G (F. 19 CEE 7, VDE0620-1 GAUGE 12) |
LX-T5-684 | CONTACT TEST GAUGE (F. 12, BS 1363-2) |
LX-T5-686 | TURNING MOMENT GAUGE (F. 15, BS 1363-2) |
LX-T5-687 | WITHDRAWAL PULL GAUGE A FOR EFFECTIVENESS OF CONTACT (F. 16, BS 1363-2) |
LX-T5-688 | WITHDRAWAL PULL GAUGE B FOR EFFECTIVENESS OF CONTACT (F. 16, BS 1363-2) |
LX-T5-689 | TEST PLUG FOR TEMPERATURE RISE (F. 30, BS 1363-2) |
LX-T5-69 | DYNAMOMETER 100 N |
LX-T5-690 | TEST PLUG FOR BREAKING CAPACITY TEST (F. 1-15, ANSI WD 6) |
LX-T5-691 | TEST PLUG FOR BREAKING CAPACITY TEST (F. 5-15, ANSI WD 6) |
LX-T5-692 | TEST PLUG FOR BREAKING CAPACITY TEST (F. 1-20, ANSI WD 6) |
LX-T5-693 | TEST PLUG FOR BREAKING CAPACITY TEST (F. 5-20, ANSI WD 6) |
LX-T5-694 | TEST FLANGED INLET FOR BREAKING CAPACITY TEST (FOR 1-15, ANSI WD 6) |
LX-T5-695 | TEST FLANGED INLET FOR BREAKING CAPACITY TEST (FOR 5-15, ANSI WD 6) |
LX-T5-696 | TEST FLANGED INLET FOR BREAKING CAPACITY TEST (FOR 1-20, ANSI WD 6) |
LX-T5-697 | TEST FLANGED INLET FOR BREAKING CAPACITY TEST (FOR 5-20, ANSI WD 6) |
LX-T5-698 | TEST PLUG R1 FOR BREAKING CAPACITY TEST (DIN 49 441) |
LX-T5-699 | TEST PLUG FOR BREAKING CAPACITY TEST (F. 4, BS 1363-1) |
LX-T5-70 | PROBE FOR CONDUIT ENTRIES DIA. 16 mm |
LX-T5-700 | TEST CAP B22d (IEC 61184, Fig. 6 ) |
LX-T5-701 | TEST CAP B22d FOR INSULATION RESISTANCE NAD HIGH-VOLTAGE TESTS (IEC 61184, Fig. 11) |
LX-T5-702 | GAUGE FOR HOLES FOR BACKPLATE LAMPHOLDERS SCREWES (IEC 61184, Fig. 3) |
LX-T5-703 | TEST HOLDER FOR TORSION TEST FOR G5 CAPPED LAMPS (IEC 61195, Fig. A.1) |
LX-T5-704 | TEST HOLDER FOR TORSION TEST FOR G13 CAPPED LAMPS (IEC 61195, Fig. A.1) |
LX-T5-705 | G5 DOUBLE ENDED "GO" GAUGE I. FOR A COMBINED PAIR OF LAMPHOLDERS (7006-47C-3) |
LX-T5-706 | G5 DOUBLE ENDED "GO" GAUGE II. FOR A COMBINED PAIR OF LAMPHOLDERS (7006-47C-3) |
LX-T5-707 | G13 DOUBLE ENDED "GO" GAUGE I. FOR A COMBINED PAIR OF LAMPHOLDERS (7006-60C-3) |
LX-T5-708 | G13 DOUBLE ENDED "GO" GAUGE II. FOR A COMBINED PAIR OF LAMPHOLDERS (7006-60C-3) |
LX-T5-71 | PROBE FOR CONDUIT ENTRIES DIA. 20 mm |
LX-T5-710 | "GO" GAUGE FOR LAMPHOLDERS G4 (Sh. 7006-72A-3) |
LX-T5-711 | GAUGE FOR CHECKING MINIMUM RETENTION FORCE IN LAMPHOLDERS G4 (Sh. 7006-72B-2) |
LX-T5-712 | GO GAUGE FOR G9 LAMPHOLDERS (Sh. 7006-129B-1) |
LX-T5-713 | GO GAUGE FOR CHECKING MAXIMUM INSERTION AND WITHDRAWAL TORQUE IN LAMPHOLDERS GU10 (Sh. 7006-121A-2) |
LX-T5-717 | GAUGE "A" FOR CHECKING LAMPHOLDERS G12 (Sh. 7006-80A-2) |
LX-T5-718 | GAUGE "B" FOR CHECKING LAMPHOLDERS G12 (Sh. 7006-80B-2) |
LX-T5-719 | GAUGE "C" FOR CHECKING LAMPHOLDERS G12 (Sh. 7006-80C-2) |
LX-T5-72 | GAUGE FOR CHECKING NON-ACCESSIBILITY OF LIVE PARTS, THROUGH SHUTTERS, AND FO LIVE PARTS OF SOCKET-OUTLETS WITH INCREASED PROTECTION; DIA. 1 x 80 mm (IEC 60884-1, F. 10) |
LX-T5-720 | STEEL DISC FOR TESTING INDUCTION HOB ELEMENTS DIA. 50 mm (IEC 60335-2-6) |
LX-T5-721 | STEEL DISC FOR TESTING INDUCTION HOB ELEMENTS DIA. 60 mm (IEC 60335-2-6) |
LX-T5-722 | STEEL DISC FOR TESTING INDUCTION HOB ELEMENTS DIA. 70 mm (IEC 60335-2-6) |
LX-T5-723 | STEEL DISC FOR TESTING INDUCTION HOB ELEMENTS DIA. 80 mm (IEC 60335-2-6) |
LX-T5-724 | STEEL DISC FOR TESTING INDUCTION HOB ELEMENTS DIA. 90 mm (IEC 60335-2-6) |
LX-T5-725 | STEEL DISC FOR TESTING INDUCTION HOB ELEMENTS DIA. 100 mm (IEC 60335-2-6) |
LX-T5-726 | STEEL DISC FOR TESTING INDUCTION HOB ELEMENTS DIA. 110 mm (IEC 60335-2-6) |
LX-T5-727 | STEEL DISC FOR TESTING INDUCTION HOB ELEMENTS DIA. 120 mm (IEC 60335-2-6) |
LX-T5-728 | STEEL DISC FOR TESTING INDUCTION HOB ELEMENTS DIA. 130 mm (IEC 60335-2-6) |
LX-T5-729 | STEEL DISC FOR TESTING INDUCTION HOB ELEMENTS DIA. 140 mm (IEC 60335-2-6) |
LX-T5-73 | GAUGE FOR CHECKING NON-ACCESSIBILITY OF LIVE PARTS, THROUGH SHUTTERS; 1 x 3 x 80 mm (IEC 60884-1, F. 9) |
LX-T5-730 | STEEL DISC FOR TESTING INDUCTION HOB ELEMENTS DIA. 150 mm (IEC 60335-2-6) |
LX-T5-731 | STEEL DISC FOR TESTING INDUCTION HOB ELEMENTS DIA. 160 mm (IEC 60335-2-6) |
LX-T5-732 | STEEL DISC FOR TESTING INDUCTION HOB ELEMENTS DIA. 170 mm (IEC 60335-2-6) |
LX-T5-733 | STEEL DISC FOR TESTING INDUCTION HOB ELEMENTS DIA. 180 mm (IEC 60335-2-6) |
LX-T5-734 | STEEL DISC FOR TESTING INDUCTION HOB ELEMENTS DIA. 190 mm (IEC 60335-2-6) |
LX-T5-735 | STEEL DISC FOR TESTING INDUCTION HOB ELEMENTS DIA. 200 mm (IEC 60335-2-6) |
LX-T5-736 | STEEL DISC FOR TESTING INDUCTION HOB ELEMENTS DIA. 210 mm (IEC 60335-2-6) |
LX-T5-737 | STEEL DISC FOR TESTING INDUCTION HOB ELEMENTS DIA. 220 mm (IEC 60335-2-6) |
LX-T5-738 | STEEL DISC FOR TESTING INDUCTION HOB ELEMENTS DIA. 230 mm (IEC 60335-2-6) |
LX-T5-739 | STEEL DISC FOR TESTING INDUCTION HOB ELEMENTS DIA. 240 mm (IEC 60335-2-6) |
LX-T5-740 | STEEL DISC FOR TESTING INDUCTION HOB ELEMENTS DIA. 250 mm (IEC 60335-2-6) |
LX-T5-741 | STEEL DISC FOR TESTING INDUCTION HOB ELEMENTS DIA. 260 mm (IEC 60335-2-6) |
LX-T5-742 | STEEL DISC FOR TESTING INDUCTION HOB ELEMENTS DIA. 270 mm (IEC 60335-2-6) |
LX-T5-743 | STEEL DISC FOR TESTING INDUCTION HOB ELEMENTS DIA. 280 mm (IEC 60335-2-6) |
LX-T5-744 | STEEL DISC FOR TESTING INDUCTION HOB ELEMENTS DIA. 290 mm (IEC 60335-2-6) |
LX-T5-745 | STEEL DISC FOR TESTING INDUCTION HOB ELEMENTS DIA. 300 mm (IEC 60335-2-6) |
LX-T5-746 | IRON BAR 100 x 20 x 2 mm (IEC 60335-2-6) |
LX-T5-747 | "GO" GAUGE FOR CHECKING MAXIMUM INSERTION TORQUE IN LAMPHOLDERS GZ10 (Sh. 7006-120A-2) |
LX-T5-748 | "GO" GAUGE FOR CHECKING MAXIMUM WITHDRAWAL TORQUE IN LAMPHOLDERS GZ10 (Sh. 7006-120A-2) |
LX-T5-749 | GAUGE B FOR CHECKING IMPOSSIBILITY OF SINGLE-POLE INSERTION OF PLUGS (VDE0620-1 Gauge&nbLX-SP;10) |
LX-T5-75 | JOINTED TEST FINGER (IEC 61032, F. 2, TEST PROBE B) |
LX-T5-750 | GO PLUG GAUGE A FOR STARTHOLDERS (IEC 60400, F. 11) |
LX-T5-751 | GO PLUG GAUGE B FOR STARTHOLDERS (IEC 60400, F. 11) |
LX-T5-752 | PLUG GAUGE FOR STARTHOLDERS FOR TESTING CONTACT MAKING & RETENTION (IEC 60400, F. 12) |
LX-T5-753 | LX-SPECIAL PLUG GAUGE FOR STARTHOLDERS FOR TESTING CONTACT MAKING (IEC 60400, F. 13) |
LX-T5-754 | TEST CAP FOR THE TEST OF CLAUSE 13 FOR LAMPHOLDERS G5 (IEC 60400, F. 14) |
LX-T5-755 | TEST CAP FOR THE TEST OF CLAUSE 13 FOR LAMPHOLDERS G13 (IEC 60400, F. 15) |
LX-T5-756 | TEST CAP FOR THE TEST OF CLAUSE 13 FOR LAMPHOLDERS 2G13-41 (IEC 60400, F. 16) |
LX-T5-757 | TEST CAP FOR THE TEST OF CLAUSE 13 FOR LAMPHOLDERS 2G13-56 (IEC 60400, F. 16) |
LX-T5-758 | TEST CAP FOR THE TEST OF CLAUSE 13 FOR LAMPHOLDERS 2G13-92 (IEC 60400, F. 16) |
LX-T5-759 | TEST CAP FOR THE TEST OF CLAUSE 13 FOR LAMPHOLDERS 2G13-152 (IEC 60400, F. 16) |
LX-T5-76 | TEST NAIL (IEC 60335-1, F. 7) |
LX-T5-760 | TEST CAP FOR THE TEST OF CLAUSE 13 FOR LAMPHOLDERS G20 (IEC 60400, F. 17) |
LX-T5-761 | TEST CAP FOR THE TEST OF CLAUSE 13 FOR LAMPHOLDERS Fa6 (IEC 60400, F. 18) |
LX-T5-762 | TEST CAP FOR THE TEST OF CLAUSE 13 FOR LAMPHOLDERS G10q (IEC 60400, F. 19) |
LX-T5-763 | TEST CAP FOR THE TEST OF CLAUSE 13 FOR LAMPHOLDERS Fa8 (IEC 60400, F. 20) |
LX-T5-765 | TEST CAP FOR THE TEST OF CLAUSE 13 FOR LAMPHOLDERS R17d (IEC 60400, F. 22) |
LX-T5-766 | TEST CAP FOR THE TEST OF CLAUSE 13 FOR LAMPHOLDERS 2G11 (IEC 60400, F. 23) |
LX-T5-767 | TEST CAP FOR THE TEST OF CLAUSE 13 FOR LAMPHOLDERS G23 AND GX23 (IEC 60400, F. 24) |
LX-T5-768 | TEST CAP FOR THE TEST OF CLAUSE 13 FOR LAMPHOLDERS GR10q (IEC 60400, F. 26) |
LX-T5-769 | TEST CAP FOR THE TEST OF CLAUSE 13 FOR LAMPHOLDERS G24 AND GY24 (IEC 60400, F. 28) |
LX-T5-77 | SMALL TEST FINGER - TEST PROBE 18 |
LX-T5-770 | TEST CAP FOR THE TEST OF CLAUSE 13 FOR LAMPHOLDERS G32 AND GY32 (IEC 60400, F. 29) |
LX-T5-771 | TEST CAP FOR THE TEST OF 17.1 FOR LAMPHOLDERS G23 (IEC 60400, F. 30) |
LX-T5-772 | TEST CAP FOR THE TEST OF 17.1 FOR LAMPHOLDERS GR8 (IEC 60400, F. 31) |
LX-T5-773 | TEST CAP FOR THE TEST OF 17.1 FOR LAMPHOLDERS GR10q (IEC 60400, F. 32) |
LX-T5-774 | TEST CAP FOR THE TEST OF 17.1 FOR LAMPHOLDERS GY10q (IEC 60400, F. 34) |
LX-T5-775 | TEST CAP FOR THE TEST OF 17.1 FOR LAMPHOLDERS 2G11 (IEC 60400, F. 35) |
LX-T5-776 | TEST CAP FOR THE TEST OF 17.1 FOR LAMPHOLDERS GX23 (IEC 60400, F. 36) |
LX-T5-777 | TEST CAP FOR THE TEST OF 17.1 FOR LAMPHOLDERS G24 AND GY24 (IEC 60400, F. 37) |
LX-T5-778 | TEST CAP FOR THE TEST OF 17.1 FOR LAMPHOLDERS G32, GX32 AND GY32 (IEC 60400, F. 38) |
LX-T5-779 | TEST CAP FOR THE TEST OF CLAUSE 13 (IEC 60400, F. 21) |
LX-T5-78 | GAUGE FOR VERIFICATION OF GROOVES, HOLES AND REVERSE TAPERS DIA. 2.5, l 100 |
LX-T5-780 | GAUGE FOR DEPTH OF NO-CONTACT TESTS FOR 10 A AND 15 A SOCKET-OUTLETS (AS3112, FIG. 3.1) |
LX-T5-781 | GAUGE FOR DEPTH OF NO-CONTACT TESTS FOR 20 A SOCKET-OUTLETS (AS3112, FIG. 3.1) |
LX-T5-782 | DEVICE FOR CHECKING THE RESISTANCE TO LATERAL STRAIN (AS3112, FIG. 3.6) |
LX-T5-783 | 10 A THREE-PIN TEST PLUG FOR CHECKING THREE-PIN FLAT-PIN 250 V MAX SOCKET-OUTLETS AGAINST THE STANDARD TEST FINGER (AS3112, FIG. C1) |
LX-T5-784 | 15 A THREE-PIN TEST PLUG FOR CHECKING THREE-PIN FLAT-PIN 250 V MAX SOCKET-OUTLETS AGAINST THE STANDARD TEST FINGER (AS3112, FIG. C1) |
LX-T5-785 | 20 A THREE-PIN TEST PLUG FOR CHECKING THREE-PIN FLAT-PIN 250 V MAX SOCKET-OUTLETS AGAINST THE STANDARD TEST FINGER (AS3112, FIG. C1) |
LX-T5-786 | 10 A THREE-PIN TEST PLUG FOR CHECKING THREE-PIN FLAT-PIN 250 V MAX SOCKET-OUTLETS AGAINST INCORRECT INSERTION OF PLUGS (AS3112, FIG. D1) |
LX-T5-787 | 15 A THREE-PIN TEST PLUG FOR CHECKING THREE-PIN FLAT-PIN 250 V MAX SOCKET-OUTLETS AGAINST INCORRECT INSERTION OF PLUGS (AS3112, FIG. D1) |
LX-T5-788 | 20 A THREE-PIN TEST PLUG FOR CHECKING THREE-PIN FLAT-PIN 250 V MAX SOCKET-OUTLETS AGAINST INCORRECT INSERTION OF PLUGS (AS3112, FIG. D1) |
LX-T5-789 | GX10q-1 NOT GO GAUGE FOR CAPS ON FINISHED LAMPS (7006-84F-1) |
LX-T5-79 | LONG TEST PIN DIA. 4, l=50 (TEST PROBE 12) |
LX-T5-790 | GX10q-2 NOT GO GAUGE FOR CAPS ON FINISHED LAMPS (7006-84F-1) |
LX-T5-791 | GX10q-3 NOT GO GAUGE FOR CAPS ON FINISHED LAMPS (7006-84F-1) |
LX-T5-792 | GX10q-4 NOT GO GAUGE FOR CAPS ON FINISHED LAMPS (7006-84F-1) |
LX-T5-793 | GX10q-5 NOT GO GAUGE FOR CAPS ON FINISHED LAMPS (7006-84F-1) |
LX-T5-794 | GX10q-6 NOT GO GAUGE FOR CAPS ON FINISHED LAMPS (7006-84F-1) |
LX-T5-795 | GY10q-1 NOT GO GAUGE FOR CAPS ON FINISHED LAMPS (7006-85E-1) |
LX-T5-796 | GY10q-2 NOT GO GAUGE FOR CAPS ON FINISHED LAMPS (7006-85E-1) |
LX-T5-797 | GY10q-3 NOT GO GAUGE FOR CAPS ON FINISHED LAMPS (7006-85E-1) |
LX-T5-798 | GY10q-4 NOT GO GAUGE FOR CAPS ON FINISHED LAMPS (7006-85E-1) |
LX-T5-799 | GY10q-5 NOT GO GAUGE FOR CAPS ON FINISHED LAMPS (7006-85E-1) |
LX-T5-80 | TEST PLUG FOR ANTENNA COAXIAL SOCKETS |
LX-T5-800 | GY10q-6 NOT GO GAUGE FOR CAPS ON FINISHED LAMPS (7006-85E-1) |
LX-T5-801 | GO GAUGES (MIN. AND MAX) FOR SOCKET OUTLET (F. 11, BS 1363-1, 1363-2) |
LX-T5-802 | CONTACT TEST GAUGE (F. 12, BS 1363-2) |
LX-T5-803 | GAUGE FOR PLUG PINS (F. 5, BS 1363-1) |
LX-T5-804 | NON-CONTACT TEST GAUGE (F. 14, BS 1363-2) |
LX-T5-805 | GAUGE 2A FOR MINIMUM OPENING OF CONTACT TUBES, 200 g (VDE0620-1 Gauge 2) |
LX-T5-806 | GAUGE 2B FOR MINIMUM OPENING OF CONTACT TUBES, 200 g (VDE0620-1 Gauge 2) |
LX-T5-807 | GAUGE 2C FOR MINIMUM OPENING OF CONTACT TUBES, 300 g (VDE0620-1 Gauge 2) |
LX-T5-808 | GAUGE 1 FOR SIZE OF ENTRY HOLES FOR PLUG PINS DIA. 5 mm (VDE0620-1 Gauge 1) |
LX-T5-809 | GAUGE 16b FOR TESTING MAX. WITHDRAWAL FORCE OF 3-PHASE 16A PLUG (VDE 0620-1 Fig.16b) |
LX-T5-81 | E14 GAUGE FOR MINIMUM DISTANCE FROM OUTER END OF SCREW SHELL TO CENTRAL CONT. |
LX-T5-810 | GAUGE 16c FOR TESTING MAX. WITHDRAWAL FORCE OF 3-PHASE 25A PLUG (VDE 0620-1 Fig.16c) |
LX-T5-811 | GO GAUGE FOR G9 BASE (Sh. 7006-129-1) |
LX-T5-812 | NOT GO GAUGE FOR G9 BASE (Sh. 7006-129A-1) |
LX-T5-813 | B15 HOLDER FOR TORQUE TEST ON LAMPS WITH BAYONET CAPS (IEC 60968 F. 3, 60432-1 F. C.1) |
LX-T5-814 | E27 HOLDER FOR TORQUE TEST ON LAMPS WITH SCREW CAPS (IEC 60432-1 F. C.2) |
LX-T5-815 | E12 HOLDER FOR TORQUE TEST ON LAMPS WITH SCREW CAPS (IEC 60432-1 F. C.2) |
LX-T5-816 | E17 HOLDER FOR TORQUE TEST ON LAMPS WITH SCREW CAPS (IEC 60432-1 F. C.2) |
LX-T5-817 | CALIBRE C1 POUR 16A (NF C 61-314) |
LX-T5-818 | CALIBRE C1 POUR 6A (NF C 61-314) |
LX-T5-819 | CALIBRE C2 POUR 6A (NF C 61-314) |
LX-T5-82 | E27 GAUGE FOR MINIMUM DISTANCE FROM OUTER END OF SCREW SHELL TO CENTRAL CONT. |
LX-T5-820 | CALIBRE C2 POUR 16A (NF C 61-314) |
LX-T5-821 | CALIBRE C3A POUR 6A (NF C 61-314) |
LX-T5-822 | CALIBRE C3B POUR 6A (NF C 61-314) |
LX-T5-823 | CALIBRE C3C POUR 6A (NF C 61-314) |
LX-T5-824 | CALIBRE C3D POUR 16A (NF C 61-314) |
LX-T5-825 | CALIBRE C3E POUR 16A (NF C 61-314) |
LX-T5-826 | CALIBRE C3F POUR 16A (NF C 61-314) |
LX-T5-827 | CALIBRE C4A POUR 6A, MASSE 300 g (NF C 61-314) |
LX-T5-828 | CALIBRE C4A POUR 6A, MASSE 150 g (NF C 61-314) |
LX-T5-829 | CALIBRE C4B POUR 16A, MASSE 400 g (NF C 61-314) |
LX-T5-83 | E40 GAUGE FOR MINIMUM DISTANCE FROM OUTER END OF SCREW SHELL TO CENTRAL CONT. |
LX-T5-830 | CALIBRE C4B POUR 16A, MASSE 200 g (NF C 61-314) |
LX-T5-831 | CALIBRE C4C POUR 16A, MASSE 400 g (NF C 61-314) |
LX-T5-832 | CALIBRE C4C POUR 16A, MASSE 200 g (NF C 61-314) |
LX-T5-833 | CALIBRE C5 POUR 6A (NF C 61-314) |
LX-T5-834 | CALIBRE C5 POUR 16A (NF C 61-314) |
LX-T5-835 | CALIBRE C6 POUR 16A (NF C 61-314) |
LX-T5-836 | CALIBRE C7A POUR 6A (NF C 61-314) |
LX-T5-837 | CALIBRE C7A POUR 16A (NF C 61-314) |
LX-T5-838 | CALIBRE C7B POUR 6A (NF C 61-314) |
LX-T5-839 | CALIBRE C7B POUR 16A (NF C 61-314) |
LX-T5-84 | E14 "NOT GO" PLUG GAUGE FOR SCREW THREADS OF LAMPHOLDERS (7006-26-4) |
LX-T5-840 | "GO" GAUGE G FOR CHECKING KEY SLOTS IN LAMPHOLDERS G24,GX24 & GY24 (Sh.7006-78G-6, Fig. 1) |
LX-T5-841 | "GO" GAUGE G FOR CHECKING KEY SLOTS IN LAMPHOLDERS G24,GX24 & GY24 (Sh.7006-78G-6, Fig. 2) |
LX-T5-842 | "GO" GAUGE G FOR CHECKING KEY SLOTS IN LAMPHOLDERS G24,GX24 & GY24 (Sh.7006-78G-6, Fig. 3) |
LX-T5-843 | "GO" GAUGE G FOR CHECKING KEY SLOTS IN LAMPHOLDERS G24,GX24 & GY24 (Sh.7006-78G-6, Fig. 4) |
LX-T5-844 | "GO" GAUGE G FOR CHECKING KEY SLOTS IN LAMPHOLDERS G24,GX24 & GY24 (Sh.7006-78G-6, Fig. 5) |
LX-T5-845 | "GO" GAUGE G FOR CHECKING KEY SLOTS IN LAMPHOLDERS G24,GX24 & GY24 (Sh.7006-78G-6, Fig. 6) |
LX-T5-846 | "GO" GAUGE G FOR CHECKING KEY SLOTS IN LAMPHOLDERS G24,GX24 & GY24 (Sh.7006-78G-6, Fig. 7) |
LX-T5-847 | "NOT GO" GAUGE FOR E26, E26/50x39, E26/51x39 & E26d CAPS ON FINISHED LAMPS (Sh. 7006-29L-4) |
LX-T5-848 | "GO" AND "NOT GO" GAUGE FOR G23 BI-PIN CAPS ON FINISHED LAMPS (Sh. 7006-69-2) |
LX-T5-849 | "GO" GAUGE FOR BI-PIN CAPS AND BASES G38 ON FINISHED LAMPS (Sh. 7006-76-1) |
LX-T5-85 | E27 "NOT GO" PLUG GAUGE FOR SCREW THREADS OF LAMPHOLDERS (7006-26-4) |
LX-T5-850 | "GO" AND "NOT GO" GAUGE FOR PINS OF BI-PIN CAPS AND BASES G38 ON FINISHED LAMPS (Sh. 7006-76A-1) |
LX-T5-851 | "GO" GAUGE FOR E17 LAMPHOLDERS (Sh. 7006-25H-1) |
LX-T5-852 | "NOT GO" GAUGE FOR E17 LAMPHOLDERS (Sh. 7006-26C-1) |
LX-T5-853 | GAUGE FOR TESTING CONTACT MAKING IN E17 LAMPHOLDERS (Sh. 7006-26E-1) |
LX-T5-854 | GAUGE FOR TESTING CONTACT MAKING IN E26 LAMPHOLDERS (Sh. 7006-25J-1) |
LX-T5-855 | GAUGE FOR TESTING UNACCEPTABLE CONTACT MAKING IN E26d LAMPHOLDERS (Sh. 7006-29M-1) |
LX-T5-856 | GAUGE FOR CHECKING MINIMUM RETENTION FORCE IN G9 LAMPHOLDERS (Sh. 7006-129C-1) |
LX-T5-857 | GAUGE FOR CHECKING CONTACT-MAKING IN G9 LAMPHOLDERS (Sh. 7006-129D-1) |
LX-T5-858 | GAUGE FOR CHECKING THE MINIMUM WITHDRAWAL TORQUE IN GU10 & GZ10 LAMPHOLDERS (Sh. 7006-120B-1) |
LX-T5-859 | GAUGES FOR TESTING INSERTION AND CONTACT-MAKING IN LAMPHOLDERS 2G13-41 (Sh. 7006-33A-2) |
LX-T5-86 | E40 "NOT GO" PLUG GAUGE FOR SCREW THREADS OF LAMPHOLDERS (7006-26-4) |
LX-T5-860 | GAUGES FOR TESTING INSERTION AND CONTACT-MAKING IN LAMPHOLDERS 2G13-56 (Sh. 7006-33A-2) |
LX-T5-861 | GAUGES FOR TESTING INSERTION AND CONTACT-MAKING IN LAMPHOLDERS 2G13-92 (Sh. 7006-33A-2) |
LX-T5-862 | GAUGES FOR TESTING INSERTION AND CONTACT-MAKING IN LAMPHOLDERS 2G13-152 (Sh. 7006-33A-2) |
LX-T5-863 | GAUGE FOR LAMPHOLDERS 2G13 FOR TESTING CONTACT-MAKING (Sh. 7006-33B-1) |
LX-T5-864 | "GO" GAUGE FOR LAMPHOLDERS 2GX13 (Sh. 7006-125-1) |
LX-T5-865 | GAUGE FOR TESTING CONTACT-MAKING IN 2GX13 LAMPHOLDERS (Sh. 7006-125C-1) |
LX-T5-866 | GAUGE FOR CHECKING THE MINIMUM RETENTION FORCE OF 2GX13 LAMPHOLDERS (Sh. 7006-125D-1) |
LX-T5-867 | GAUGE "A" FOR LAMPHOLDERS S14d (Sh. 7006-112D-1) |
LX-T5-868 | GAUGE "B1" FOR LAMPHOLDERS S14d (Sh. 7006-112E-1) |
LX-T5-869 | GAUGE "B2" FOR LAMPHOLDERS S14d (Sh. 7006-112E-1) |
LX-T5-87 | E14 "GO" PLUG GAUGE FOR SCREW THREADS (7006-25-7) |
LX-T5-870 | GAUGE "A" FOR LAMPHOLDERS S14s (Sh. 7006-112A-1) |
LX-T5-871 | GAUGE "B" FOR LAMPHOLDERS S14s (Sh. 7006-112B-1) |
LX-T5-872 | GAUGE "C" FOR LAMPHOLDERS S14s (Sh. 7006-112C-1) |
LX-T5-873 | CONTACT GAUGE FOR CHECKING THE EARTHING CONTACT OF 2,5 A CONNECTORS (IEC 60320-1, F. 27) |
LX-T5-874 | NO CONTACT GAUGE FOR CHECKING THE EARTHING CONTACT OF 2,5 A CONNECTORS (IEC 60320-1, F. 27) |
LX-T5-875 | CONTACT GAUGE FOR CHECKING THE EARTHING CONTACT OF 16 A CONNECTORS (IEC 60320-1, F. 27) |
LX-T5-876 | NO CONTACT GAUGE FOR CHECKING THE EARTHING CONTACT OF 16&nbLX-SP;A CONNECTORS (IEC 60320-1, F. 27) |
LX-T5-877 | TEST PLUG WITH SOLID PINS FOR NORMAL OPERATION TEST (Cl. 18, BS 1363-2) |
LX-T5-878 | SET OF SOLID PINS FOR LX-T5-877 (3 pcs. Cl. 18, BS 1363-2) |
LX-T5-879 | E10, EP10, EY10 "NOT GO" PLUG GAUGE FOR SCREW THREADS OF LAMPHOLDERS (7006-26-4) |
LX-T5-88 | E27 "GO" GAUGE FOR LAMPHOLDERS (7006-25A-2) |
LX-T5-880 | E39 "NOT GO" PLUG GAUGE FOR SCREW THREADS OF LAMPHOLDERS (7006-26-4) |
LX-T5-881 | ACCEPTANCE GAUGE FOR B22d CAPS INTENDED FOR AUTOMATIC WIRE THREADING (7006-3-1) |
LX-T5-882 | GAUGE BY22d FOR TESTING THE INSERTION OF CAPS IN LAMPHOLDERS (7006-4A-2) |
LX-T5-883 | "GO" GAUGE FOR CAP B22d-3 (25x26) ON FINISHED LAMPS (7006-19-2) |
LX-T5-89 | E40 "GO" PLUG GAUGE FOR SCREW THREADS (7006-25-7) |
LX-T5-90 | E10 "GO" PLUG GAUGE FOR SCREW THREADS (7006-25-7) |
LX-T5-91 | E10 "NOT GO" PLUG GAUGE FOR SCREW THREADS OF LAMPHOLDERS (7006-26-4) |
LX-T5-92 | E40 GAUGE FOR TESTING PROTECTION AGAINST BULB-NECK DAMAGE AND FOR TESTING CONTACT-MAKING IN LAMPHOLDERS (7006-23-3) |
LX-T5-95 | E40 PLUG GAUGE FOR LAMPHOLDERS FOR TESTING PROTECTION AGAINST ACCIDENTAL CONTACT (7006-24-3) |
|
|
LX-T6-01 | VARIABLE RATIO TRANSFORMER (270 V, 30 A) |
LX-T6-04 | 3-PHASE STABILIZED AC POWER SUPPLY UNIT 3 x 0-450V, 40A |
LX-T6-07 | 3-PHASE AC POWER SUPPLY UNIT 3 x 0-550V, 45A |
LX-T6-12 | 4 STEP DOUBLE PROGRAMMABLE TIMER |
LX-T6-16 | PROGRAMMABLE OFF SWILX-TCHING COUNTER |
LX-T6-17 | OFF SWILX-TCHING COUNTER WITH TIMER |
LX-T6-19 | MOTOR CONTROLLER 200 |
LX-T6-20 | PNEUMATIC DRIVE UNIT |
LX-T6-21 | SWILX-TCH ACTUATOR CONTROL UNIT |
LX-T6-21A | SWILX-TCH ACTUATOR (LONGITUDINAL MOVEMENT) |
LX-T6-21B | SWILX-TCH ACTUATOR (LONGITUDINAL AND CIRCULAR MOVEMENT) |
LX-T6-22 | 3-PHASE AC POWER SUPPY UNIT 3 x 0-520V, 20A (23 kVA) |
LX-T6-46 | COORDINATE HOLDER |
LX-T6-50 | RESISTANCE BATTERY 15 kW |
LX-T6-60 | AIR CORE INDUCTOR 100 mH, 25 A |
LX-T6-64 | AIR CORE INDUCTOR Imax 63 A, cosj max. 0.6 |
LX-T6-65 | IRON CORE INDUCTOR Imax 40 A, cosj max. 0.3 |
LX-T6-70 | TUNGSTEN LAMP LOAD (BATTERY WITH 60x200W LAMPS) |
LX-T6-71 | BENCH FOR MECHANICAL TESTS |
|
|
LX-T6-91 | TEST SYSTEM FOR SWILX-TCHES (3 PHASE 3 x 34 kW, max. 440V, 91A, IEC 60669-1) |
LX-T6-92 | POWER SUPPLY UNIT WITH NON INDUCTIVE RESISTANCE BATTERY (0-280 V, 15 A, 3,9 kVA, BS 1363-2 Cl. 17,18) |
LX-T6-93 | POWER SUPPLY UNIT WITH INDUCTIVE AND RESISTIVE LOAD (0-275 V, 125 A, 0,3 cos ?) |
LX-T6-94 | POWER SUPPLY UNIT WITH INDUCTIVE AND RESISTIVE LOAD (0-275 V, 50 A, 0,3 cos ?) |
LX-TC150WB | TEMPERATURE CHAMBER WITH WATER BATH FOR DETERMINATION OF FROST RESISTANCE OF NATURAL STONE 150l, (600 x 500 x 400 mm), -20°C to + 100 °C (EN 12371) |
LX-TK265C | TEMPERATURE CHAMBER 265 L, T= -40..50 deg C |
LX-TK600C | TEMPERATURE CHAMBER 612 L, T= -40..50 deg C |
LX-TK600H | TEMPERATURE CHAMBER 612 L, T= +35..+300 deg C |