E14 Caps Gauges Instructions

Related gauges for E14 caps:

1. Go gauge for E14 caps on finished lamps, 7006-27F-1;

Purpose: 

To check the maximum dimensions of the screw thread and dimension T1 minimum of E14 caps on finished lamps.

Testing: 

When the cap on a finished lamp has been screwed into the gauge as far as it will go, the centre contact shall be co-planar with, or project beyond surface X.

 


2. Go gauge for dimension "S1" of E14 caps on finished lamps, 7006-27G-1;

Purpose: 

To check the dimensions S1 minimum and S1 maximum of E14 caps on finished lamps.

Testing: 

When the cap on a finished lamp has been screwed into the gauge as far as it will go, the plunger surface W shall be co-planer with or project beyond surface X but it shall not project beyond surface Y.

 


3. Not go gauge for E14 caps on finished lamps, 7006-28B-1; 

Purpose: 

To check the minimum outside (major) diameter of the screw thread, dimension d, of caps E14 on finished lamps.

Testing: 

When the gauge is placed over the thread of the cap on a finished lamp, held cap uppermost, the centre contact shall not project beyond surface X.

Only the weight of the gauge itself shall be used in the test.

 


4. Gauge for finished lamps fitted with E14 caps for testing contact making, 7006-54-2;

Purpose: 

To check lamp dimensions for contact making in IEC holders.

Testing: 

The shape of the lamp with regard to the fit in the lampholder is assumed to be correct if the lamp can be pushed into the gauge till plane W reaches plane V or projects beyond it.

 


5. Gauge for finished lamps fitted with E14 caps for testing protection against accidental contact, 7006-55-2.

Purpose: 

To check protection against accidental contact.

Testing: 

The shape of the lamp with regard to protection against accidental contact is assumed to be correct if the test sample being pushed as far as possible into the gauge, plane W does not protrude beyond plane V.

The application of this gauge is restricted to the following lamps when they are fitted with E14 caps, in accordance with sheet 7004-23:

Candle lamps

Round bulb lamps

Domestic tubular lamps

Pygmy lamps.

    Standard:       IEC 61032 IEC 60061 IEC 60335 IEC 60529 IEC 60068 IEC 60695 VDE 0620 UL AS/NZS3112
    TAG:
IEC Test Probe Go No Go Gauge Spring Impact Hammer Integrating Sphere UL Probe Test IP Tester Test Equipment
 
Glow Wire Tester Impact Test Hammer Go Gauge UL Test Finger Probe Hipot Tester Test Probe Needle Impact Testing Machine
  Español   Español Svenska   Svenska لعربية   لعربية русский   русский Português   Português 中国  中国 Polski   Polski Română   Română Dansk   Dansk suomi   suomi
  Français   Français hrvatski   hrvatski Ελληνικά   Ελληνικά Nederlands   Nederlands česky   česky Deutsch   Deutsch 日本の   日本の Italia   Italia български   български นไทย   นไทย
test probe