Julixing Instruments

Julixing Instruments

 
Julixing Instruments

Company News

B22d Caps Gauges Instructions

Related gauges for B22d caps:

1. Acceptance gauge for B22d caps intended for automatic wire threading, 7006-3-1;

Purpose: 

To check the suitability of automatic wire threading of B22d caps as shown on sheet 7004-10.

Testing: 

The cap shall be assumed to be correct if can be inserted smoothly into the gauge until the contact places of the cap touch surface Y of the gauge.

 


2. Gauges for testing the insertion of caps in lampholders B22d, 7006-4A-2; 

Purpose: 

To check B22d cap dimensions for insertion of the cap on the finished lamp in the lampholder.

Testing: 

Without undue force it shall be possible to insert the cap into the gauge until the pins have passed completely through the slots.

 


3. Gauge for testing the retention of B15d and B22d caps in the holder, 7006-4B-1;

Purpose: 

To check cap dimensions for retention of the cap on the finished lamp in the lampholder.

Testing: 

The cap of the lamp shall enter the gauge from surface X, until the pins have passed through slots Q. The caps is then turned through 90°for one pin to enter the gauged pin slot. With a slight pull the pin shall not pass surface Y. The test is made twice, the lamp being rotated through 180°,so that each pin in turn is gauged.

 


4. Not go gauges for caps on finished lamps B22, 7006-10-8;

Purpose: 

To check dimension A in, of caps B22 on finished lamps.

Testing: 

Caps on finished lamps shall be assumed to be correct if the gauge does not pass over the cap by its own weight.

 


5. Go gauges for caps on finished lamps BA9, B15, BA15 & B22, 7006-11-8.

Purpose: 

To check dimensions A max., N min. D1 min., D1 max., and the diametrical position of the pins of caps B22 on finished lamps.

Testing: 

The cap shall enter the gauge until the pins have passed through the slot Q. The cap is then turned through a small angle and is pressed so that the pins are in close contact with surface S.

In this position, the contact making surface shall not be below surface X nor shall it project beyond surface Z. 

    Standard:       IEC 61032 IEC 60061 IEC 60335 IEC 60529 IEC 60068 IEC 60695 VDE 0620 UL AS/NZS3112
    TAG:
IEC Test Probe Go No Go Gauge Spring Impact Hammer Integrating Sphere UL Probe Test IP Tester Test Equipment
 
Glow Wire Tester Impact Test Hammer Go Gauge UL Test Finger Probe Hipot Tester Test Probe Needle Impact Testing Machine
  Español   Español Svenska   Svenska لعربية   لعربية русский   русский Português   Português 中国  中国 Polski   Polski Română   Română Dansk   Dansk suomi   suomi
  Français   Français hrvatski   hrvatski Ελληνικά   Ελληνικά Nederlands   Nederlands česky   česky Deutsch   Deutsch 日本の   日本の Italia   Italia български   български นไทย   นไทย
test probe